SIEMENS
SCLD69600NGT - 600Amp Circuit Breaker
SCLD69600NGT - 600Amp Circuit Breaker
Couldn't load pickup availability
SCLD69600NGT - 600Amp Circuit Breaker
The Siemens SCLD69600NGT circuit breaker is a 600-amp, three-pole molded case circuit breaker (MCCB) from the Siemens SENTRON low-voltage product line. Designed for your electrical distribution systems requiring an LD-frame breaker, this model features a 600V AC voltage rating, current-limiting breaking-capacity construction, and a SensiTrip LSIG electronic trip unit. With an interrupting rating of 100kAIC at 600V AC and 150kAIC at 480V AC, it provides clear electrical characteristics to evaluate compatibility with existing commercial and industrial equipment.
Key Features and Benefits
- 600-Amp Current Rating: Provides a defined 600A breaker rating for electrical distribution applications requiring this current capacity.
- Three-Pole Configuration: Designed for compatible three-phase electrical systems that require a three-pole molded-case circuit breaker.
- 600V AC Voltage Rating: Suitable for consideration in systems operating within the manufacturer's specified voltage rating.
- LD-Frame Design: Provides a specific frame configuration for evaluating form and fit in compatible existing electrical equipment.
- SensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with the LSIG functions identified for this catalog number.
- Long-Time Protection: Addresses sustained overcurrent conditions according to the applicable electronic trip characteristics and settings.
- Short-Time Protection: Includes a short-time protection function for qualifying overcurrent conditions, subject to the trip unit's configuration and settings.
- Instantaneous Protection: Provides a trip function for qualifying high-current faults without an intentional short-time delay.
- Ground-Fault Protection: Includes the ground-fault function identified by the LSIG designation for systems designed to use this protection element.
- Included TA2J6500 Line-Side Lugs: Supplied with the manufacturer-specified line-side terminal lugs.
- Included TA2J6500 Load-Side Lugs: Also includes matching load-side lugs for the stated conductor ranges.
Technical Specifications
-
Manufacturer: Siemens
-
Product Family: SENTRON
-
Product Type: Low-Voltage Molded Case Circuit Breaker (MCCB)
-
Catalog Number / MFN: SCLD69600NGT
-
Siemens Article Number: US2
-
UPC: 783643217713
-
Rated Current: 600 Amps
-
Number of Poles: 3
-
Rated Voltage: 600V AC
-
Interrupting Capacity at 600V AC: 100kAIC
-
Interrupting Capacity at 480V AC: 150kAIC
-
Frame Type: LD Frame
-
Trip Unit Type: Electronic Trip Unit (ETU)
-
Trip System: Siemens SensiTrip
-
Trip Function Designation: LSIG
-
Long-Time Protection: Included
-
Short-Time Protection: Included
-
Instantaneous Protection: Included
-
Ground-Fault Protection: Included
-
Breaker Temperature Designation: Standard 40°C (104°F)
-
Breaking-Capacity Construction: Current-limiting
-
Line-Side Lugs: TA2J6500, included
-
Load-Side Lugs: TA2J6500, included
-
Copper Wire Range: 3/0 AWG–500 kcmil
-
Aluminum Wire Range: 4/0 AWG–500 kcmil
-
Width: 7.5 inches
-
Height: 17.86 inches
-
Depth: 4 inches
-
Dimensions (W × H × D): 7.5 × 17.86 × 4 inches
-
Net Weight: 34.00 lb
-
Manufacturer-Stated Standards: Meets UL 489 / IEC 60947-2
-
Country of Origin: Mexico
-
Commodity Code: 8536200020
-
Siemens Product Group: 3741
-
Catalog ID: LV10.1
-
Siemens Group Code: P360
-
Export Classification: ECCN EAR99 / AL N
Material Compliance and Certifications
The Siemens SCLD69600NGT includes manufacturer-provided standards and environmental information to support equipment documentation, maintenance planning, and compatibility reviews.
- UL 489: Siemens states that the SCLD69600NGT meets UL 489 requirements applicable to molded case circuit breakers.
- IEC 60947-2: Siemens also identifies IEC 60947-2 among the standards met by this breaker.
- RoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.
- REACH Article 33: The manufacturer provides REACH Article 33 duty-to-inform information based on the applicable candidate list.
- WEEE Information: Siemens identifies no take-back obligation under the WEEE 2012/19/EU field in its product data.
Where It Works Best
The Siemens SCLD69600NGT 600A molded case circuit breaker is best suited for existing electrical systems where its electrical ratings, LSIG trip functions, physical dimensions, and terminal connections match approved equipment requirements. Potential applications include:
- Existing Commercial Electrical Distribution
- Industrial Electrical Systems
- Legacy Siemens Switchboards
- 600-Amp Feeder Circuit Applications
- 480V AC Distribution Systems
- 600V AC Distribution Systems
- Three-Phase Power Distribution
- LD-Frame Breaker Replacements
- SensiTrip LSIG Electronic Trip Applications
- Ground-Fault Protection Applications
- Copper-Conductor Installations
- Aluminum-Conductor Installations
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.