SIEMENS
SCLD69600 - 600Amp Circuit Breaker
SCLD69600 - 600Amp Circuit Breaker
Couldn't load pickup availability
SCLD69600 - 600Amp Circuit Breaker
The Siemens SCLD69600 is a 600-amp, three-pole molded-case circuit breaker from the Siemens SENTRON family, designed for electrical distribution equipment that requires an LD-frame breaker with SensiTrip electronic protection. Rated for 600V AC and featuring a 100kAIC interrupting rating at 600V AC, this breaker provides a specific combination of electrical ratings, physical dimensions, and trip functions for compatible installations. Whether you're maintaining an existing switchboard or finding a replacement for an installed breaker, the SCLD69600 provides clear specifications to help you determine whether it's the right match.
Key Features and Benefits
- 600-Amp Current Rating: Designed for electrical distribution applications requiring a 600A molded case circuit breaker, subject to the equipment's approved configuration and electrical design.
- Three-Pole Configuration: Provides three-pole switching and overcurrent protection for compatible three-phase electrical systems.
- 600V AC Voltage Rating: Suitable for evaluation in equipment operating at voltages up to the breaker's specified 600V AC rating.
- Siemens SENTRON Construction: Part of Siemens' low-voltage SENTRON molded case circuit breaker range, with documented electrical and physical specifications.
- LD-Frame Design: Uses the Siemens LD frame, allowing you to compare its dimensions and construction with the requirements of compatible existing equipment.
- SensiTrip Electronic Trip Unit: Incorporates Siemens SensiTrip electronic overcurrent protection with the LI functions specified for this catalog number.
- Long-Time Overcurrent Protection: The long-time trip function protects against sustained overcurrent conditions per the unit's specified characteristics.
- Instantaneous Overcurrent Protection: The instantaneous trip function responds to qualifying high-current fault conditions without an intentional short-time delay.
- Line-Side Lugs Included: Supplied with TA2J6500 line-side lugs to help identify the required terminal arrangement during compatibility checks.
- Load-Side Lugs Included: Also includes TA2J6500 load-side lugs for the manufacturer-specified conductor sizes.
Technical Specifications
-
Manufacturer: Siemens
-
Product Family: Siemens SENTRON
-
Product Type: Low-voltage molded case circuit breaker (MCCB)
-
Catalog Number: SCLD69600
-
Manufacturer Part Number (MFN): SCLD69600
-
Siemens Article Number: US2
-
Product Description: SENTRON molded case circuit breaker with electronic trip unit
-
Rated Current: 600 Amps
-
Number of Poles: 3
-
Rated Voltage: 600V AC
-
Interrupting Rating at 600V AC: 100kAIC
-
Interrupting Rating at 480V AC: 150kAIC
-
Breaker Frame: LD Frame
-
Trip Unit: Siemens SensiTrip electronic trip unit (ETU)
-
Trip Functions: LI – Long-Time and Instantaneous
-
Long-Time Protection: Yes
-
Instantaneous Protection: Yes
-
Short-Time Delay Protection: Not specified for this LI configuration
-
Ground-Fault Protection: Not specified for this LI configuration
-
Breaking-Capacity Construction: Current-limiting
-
Standard Temperature Reference: 40°C (104°F)
-
Line-Side Lugs: TA2J6500, included
-
Load-Side Lugs: TA2J6500, included
-
Copper Wire Range: 3/0 AWG to 500 kcmil
-
Aluminum Wire Range: 4/0 AWG to 500 kcmil
-
Width: 7.5 inches
-
Height: 17.86 inches
-
Depth: 4 inches
-
Dimensions (W × H × D): 7.5 × 17.86 × 4 inches
-
Net Weight: 34.00 lb
-
Applicable Standards Identified by Siemens: UL 489 / IEC 60947-2
-
UPC: 783643217683
-
Commodity Code: 8536200020
-
Siemens Product Group: 3741
-
Catalog ID: LV10.1
-
Group Code: P360
-
Country of Origin: Mexico
Material Compliance and Certifications
The Siemens SCLD69600 includes manufacturer-documented standards and environmental information that may be relevant to equipment maintenance records, replacement evaluations, and project documentation.
- UL 489: Siemens identifies the SCLD69600 as meeting UL 489, the standard for molded-case circuit breakers and related protective devices.
- IEC 60947-2: Siemens also identifies the breaker as meeting IEC 60947-2, the international standard covering low-voltage circuit breakers.
- RoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.
- REACH Article 33: Siemens provides REACH Article 33 candidate-list substance information for this product.
- WEEE Information: Siemens lists no take-back obligation for this product under its WEEE 2012/19/EU product data field.
Where It Works Best
The Siemens SCLD69600 600A circuit breaker is considered for electrical systems where its exact ratings, configuration, and physical characteristics match the equipment's requirements. Potential applications include:
- Existing Commercial Electrical Distribution
- Industrial Electrical Systems
- Legacy Siemens Switchboards
- 600-Amp Feeder Circuit Applications
- 480V AC Distribution Systems
- 600V AC Distribution Systems
- Three-Phase Power Distribution
- LD-Frame Breaker Replacements
- SensiTrip LI Electronic Trip Applications
- Copper-Conductor Installations
- Aluminum-Conductor Installations
- Facility Electrical Maintenance Programs
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.