SIEMENS

SCLD69500NT - 500Amp Circuit Breaker

SCLD69500NT - 500Amp Circuit Breaker

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

SCLD69500NT - 500Amp Circuit Breaker

The Siemens SCLD69500NT circuit breaker is a 500-amp, 3-pole molded case circuit breaker (MCCB) designed for use in your compatible low-voltage electrical distribution equipment. Part of the Siemens SENTRON family, this LD-frame breaker combines a 600V AC voltage rating, a 100kAIC interrupting capacity at 600V AC, and a SensiTrip electronic trip unit with long-time, short-time, and instantaneous (LSI) protection functions. For electrical contractors, facility maintenance teams, and equipment owners working with existing Siemens systems, the SCLD69500NT provides clear specifications to evaluate an exact form, fit, and functional replacement.

Key Features and Benefits

  • 500-Amp Current Rating: Designed for electrical distribution circuits requiring a 500A molded case circuit breaker.
  • Three-Pole Configuration: Provides three-pole circuit protection for compatible three-phase electrical systems.
  • 600V AC Voltage Rating: Supports evaluation for low-voltage installations operating within the breaker's specified voltage rating.
  • Siemens SENTRON Construction: Part of Siemens' established low-voltage molded case circuit breaker family.
  • LD-Frame Design: Identifies the frame configuration needed when checking compatibility with existing electrical equipment.
  • SensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with the specified LSI protection functions.
  • Long-Time Overcurrent Protection: Addresses sustained overcurrent conditions according to the electronic trip unit's operating characteristics.
  • Short-Time Protection: Provides a short-time trip function for qualifying overcurrent conditions, subject to the system's coordination requirements.
  • Instantaneous Short-Circuit Protection: Includes an instantaneous trip function for high-level short-circuit conditions.
  • Included TA2J6500 Lugs: Features specified line-side and load-side connection lugs for compatible conductors.

Technical Specifications

  • Manufacturer: Siemens
  • Product Family: SENTRON
  • Catalog Number / MFN: SCLD69500NT
  • Siemens Article Number: US2
  • Product Type: Low-voltage molded case circuit breaker (MCCB)
  • Frame Type: LD frame
  • Rated Current: 500 amps
  • Number of Poles: 3
  • Rated Voltage: 600V AC
  • Interrupting Capacity at 600V AC: 100kAIC
  • Interrupting Capacity at 480V AC: 150kAIC
  • Trip Unit: Siemens SensiTrip electronic trip unit (ETU)
  • Trip Functions: LSI — long-time, short-time, instantaneous
  • Ground-Fault Trip Function: Not specified for this LSI model
  • Standard Breaker Temperature Designation: 40°C
  • Breaking-Capacity Construction: Current-limiting
  • Line-Side Lugs: TA2J6500
  • Load-Side Lugs: TA2J6500
  • Copper Conductor Range: 3/0 AWG–500 kcmil
  • Aluminum Conductor Range: 4/0 AWG–500 kcmil
  • Width: 7.5 inches
  • Height: 17.86 inches
  • Depth: 4 inches
  • Dimensions (W × H × D): 7.5 × 17.86 × 4 inches
  • Net Weight: 34.00 lb
  • Referenced Standards: UL 489 / IEC 60947-2
  • UPC: 783643217669
  • Commodity Code: 8536200020
  • Siemens Product Group: 3741
  • Catalog ID: LV10.1
  • Group Code: P360
  • Country of Origin: Mexico

Material Compliance and Certifications

  • UL 489: Siemens identifies the SCLD69500NT as meeting UL 489 requirements for molded case circuit breakers.
  • IEC 60947-2: Siemens also specifies that the breaker meets IEC 60947-2, the international standard addressing low-voltage circuit breakers.
  • RoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.
  • REACH Article 33: Siemens provides a REACH Article 33 information reference concerning substances on the current candidate list. This reference should not be interpreted as an unrestricted declaration covering every REACH obligation.
  • WEEE Take-Back Obligations: Siemens lists the WEEE (2012/19/EU) take-back obligations field as "5."

Where It Works Best

  • Compatible Legacy Siemens Switchboards
  • 500A Electrical Distribution Circuits
  • 480V AC Distribution Systems
  • 600V AC Distribution Systems
  • Industrial Electrical Equipment Maintenance
  • Commercial Power Distribution Equipment
  • LSI Electronic Trip Applications
  • Existing LD-Frame Installations
  • Copper-Conductor Connections
  • Aluminum-Conductor Connections
  • Facility Electrical Maintenance Programs



Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.

View full details