SIEMENS

SCLD69300G - 300Amp Circuit Breaker

SCLD69300G - 300Amp Circuit Breaker

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

SCLD69300G - 300Amp Circuit Breaker

The Siemens SCLD69300G circuit breaker is a 300-amp, 3-pole molded-case circuit breaker (MCCB) for your compatible commercial and industrial electrical distribution systems. As part of the Siemens SENTRON family, this LD-frame circuit breaker features an electronic SensiTrip trip unit with long-time, instantaneous, and ground-fault protection. For electricians, maintenance teams, and facility managers working with existing electrical equipment, the SCLD69300G offers a specific combination of electrical ratings, protection functions, and physical dimensions that can help maintain the original system configuration.

Key Features and Benefits

  • 300-Amp Current Rating: Designed for electrical applications requiring a 300A molded case circuit breaker.
  • Three-Pole Configuration: Supports compatible three-phase power distribution systems.
  • 600V AC Voltage Rating: Intended for electrical systems operating within the manufacturer's specified voltage rating.
  • LD-Frame Construction: Supports identification of the correct breaker frame for compatible electrical assemblies.
  • Electronic SensiTrip Unit: Incorporates electronic overcurrent protection with LIG trip functions.
  • Long-Time Protection: Addresses sustained overcurrent conditions according to the trip unit's characteristics.
  • Instantaneous Protection: Responds to short-circuit conditions through the instantaneous trip function.
  • Ground-Fault Protection: Adds a ground-fault trip function for systems designed around LIG protection.
  • Current-Limiting Design: Features Siemens' specified current-limiting breaking-capacity construction.
  • TA2J6500 Line and Load Lugs: Includes designated conductor connections on both sides of the breaker.
  • Copper and Aluminum Conductor Compatibility: Accommodates the specified conductor-size ranges for each material.

Technical Specifications

  • Manufacturer: Siemens
  • Product Family: SENTRON
  • Catalog Number: SCLD69300G
  • Manufacturer Part Number (MFN): SCLD69300G
  • Article Number: US2
  • Product Type: Molded Case Circuit Breaker (MCCB)
  • Frame Type: LD
  • Rated Current: 300 Amps
  • Number of Poles: 3
  • Rated Voltage: 600V AC
  • Interrupting Capacity at 600V AC: 100kAIC
  • Interrupting Capacity at 480V AC: 150kAIC
  • Trip Unit Type: Electronic Trip Unit (ETU)
  • Trip Technology: Siemens SensiTrip
  • Trip Configuration: LIG
  • Long-Time Protection: Yes
  • Instantaneous Protection: Yes
  • Ground-Fault Protection: Yes
  • Short-Time Protection: Not included in the specified LIG configuration
  • Breaking-Capacity Design: Current Limiting
  • Standard Breaker Temperature Reference: 40°C
  • Line-Side Lugs: TA2J6500
  • Load-Side Lugs: TA2J6500
  • Copper Conductor Range: 3/0 AWG–500 kcmil
  • Aluminum Conductor Range: 4/0 AWG–500 kcmil
  • Width: 7.50 inches
  • Height: 17.86 inches
  • Depth: 4.00 inches
  • Net Weight: 34.00 lb
  • UPC: 783643217577
  • Catalog ID: LV10.1
  • Siemens Product Group: 3741
  • Group Code: P360
  • Commodity Code: 8536200020
  • Country of Origin: Mexico

Material Compliance and Certifications

The Siemens SCLD69300G molded case circuit breaker has manufacturer-documented electrical standards and material-compliance information relevant to its intended use in low-voltage electrical distribution equipment.

  • UL 489: Siemens states that the SCLD69300G meets UL 489 requirements for molded case circuit breakers.
  • IEC 60947-2: Siemens identifies the breaker as meeting IEC 60947-2 requirements for low-voltage circuit breakers.
  • RoHS Directive: Siemens reports compliance with applicable substance restrictions since March 30, 2009.
  • REACH Article 33: Manufacturer documentation references the duty to inform regarding substances included on the applicable REACH candidate list.
  • WEEE Directive (2012/19/EU): Siemens identifies a take-back obligation classification of 5.

Where It Works Best

  • Compatible Commercial Electrical Distribution Systems
  • Industrial Power Distribution Equipment
  • Existing Siemens LD-Frame Breaker Installations
  • Three-Phase Electrical Distribution Systems
  • 300-Amp Feeder Circuit Protection
  • Compatible 480V AC Electrical Systems
  • Compatible 600V AC Electrical Systems
  • Equipment Requiring LIG Electronic Trip Protection
  • Electrical Assemblies Requiring Ground-Fault Trip Functionality
  • Commercial Facility Electrical Maintenance
  • Industrial Facility Electrical Maintenance
  • Legacy Switchboards Approved for This Breaker Configuration

Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.

View full details