EATON
NCLR400 - 400 Amp Fuse
NCLR400 - 400 Amp Fuse
Couldn't load pickup availability
NCLR400 - 400 Amp Fuse
Need a 400-amp Class R fuse for a compatible electrical system? The NCLR400 is a cartridge-style, time-delay fuse rated for 400 amps and 600 VAC, with a 200 kA interrupting rating. It's also current-limiting, giving you the combination of specifications needed for demanding electrical applications.
Because this is a time-delay fuse, it can handle temporary current surges without reacting the same way an instantaneous fuse would. That can be important in equipment where brief inrush currents are part of normal operation.
The NCLR400 measures 8.63 inches high, 2 inches wide, and 2 inches deep. If you're replacing an existing fuse, check those dimensions along with the amperage, voltage, Class R designation, and interrupting rating. A fuse can look like the right replacement and still have different electrical characteristics, so matching the complete specification matters.
Key Features and Benefits
- 400 amp capacity for equipment requiring a 400A fuse
- Rated for 600 VAC
- 200 kA interrupting rating
- Time-delay design for applications where temporary current surges may occur
- Current-limiting Class R construction
- Traditional cartridge-style format
- Non-indicating design
- Clearly defined dimensions make it easier to compare against an existing fuse
Technical Specifications
-
Part Number: NCLR400
-
Type: NCLR
-
Fuse Class: Class R
-
Amperage: 400 A
-
Voltage: 600 VAC
-
A.I.C. / Interrupting Rating: 200 kA
-
Operation: Time-Delay
-
Current Limiting: Yes
-
Style: Cartridge
-
Indication: Non-Indicating
-
Dimensions:
- Height: 8.63 in.
- Width: 2.0 in.
- Depth: 2.0 in.
Material Compliance and Certifications
The available NCLR400 specifications did not include material compliance, environmental certifications, or agency listing information. If your installation requires a particular certification or compliance standard, confirm that requirement against the documentation for the exact fuse before installation.
Where It Works Best
The NCLR400 fuse is intended for compatible electrical equipment calling for a 400 amp, 600 VAC, Class R time-delay fuse with current-limiting characteristics.
It can be a practical replacement option when those specifications match the fuse the equipment originally required. Before swapping, check more than amperage. Fuse class, voltage, interrupting rating, time-delay characteristics, and physical size should all match the application requirements.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.