EATON
NCLR15 - 15Amp Fuse
NCLR15 - 15Amp Fuse
Couldn't load pickup availability
NCLR15 - 15Amp Fuse
The NCLR15 is a 15-amp, 600 VAC Class R fuse designed to protect compatible commercial and industrial electrical equipment. Its time-delay design lets it handle normal short-term current increases without opening unnecessarily. With a 200 kA A.I.C. rating at 600 VAC, the NCLR15 also provides the interrupting capacity required for applications with high available fault current.
This cartridge-style, current-limiting fuse has a non-indicating design. It measures 2 inches long and approximately 0.56 inches wide and deep, so it's easy to compare with the fuse you're replacing. If your equipment calls for an NCLR15 15 amp Class R fuse, check the voltage, amperage, fuse class, time-delay requirement, and dimensions before replacing it.
Key Features and Benefits
- 15 amp, 600 VAC rating for compatible electrical applications
- 200 kA A.I.C. at 600 VAC for high fault-current applications
- Time-delay operation helps accommodate temporary current increases
- Class R current-limiting design provides overcurrent and fault-current protection
- Cartridge-style construction for use with compatible fuse holders
- Non-indicating design with no visual blown-fuse indicator
- Compact 2.0" × 0.56" × 0.56" dimensions
Technical Specifications
-
Part Number: NCLR15
-
Type: NCLR
-
Fuse Class: Class R
-
Amperage: 15 A
-
Voltage Rating: 600 VAC
-
A.I.C. Rating: 200 kA @ 600 VAC
-
Fuse Style: Cartridge
-
Operation: Time-Delay
-
Current Limiting: Yes
-
Indicating: No
-
Dimensions:
- Height: 2.0 in.
- Width: 0.56 in.
- Depth: 0.56 in.
Material Compliance and Certifications
Specific agency certifications and material-compliance information were not included with the supplied NCLR15 specifications. If your application requires a particular UL, CSA, RoHS, or other compliance designation, confirm that requirement against the appropriate product documentation rather than assuming certification based on the fuse type.
Where It Works Best
The NCLR15 is intended for compatible electrical equipment requiring a 15 amp, 600 VAC Class R time-delay fuse. Its time-delay characteristics can help in applications where brief current increases are expected during normal operation, while its 200 kA A.I.C. rating provides substantial interrupting capacity.
For replacement applications, match more than just the physical size and amperage. Before installation, check the required fuse class, voltage, amperage, interrupting rating, and time-delay characteristics against the equipment specifications.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.