MCP13300R - 30Amp Motor Circuit Protector
MCP13300R - 30Amp Motor Circuit Protector
Couldn't load pickup availability
MCP13300R - 30Amp Motor Circuit Protector
If you are replacing a 30-amp motor circuit protector in existing equipment, the catalog number is only the beginning. The MCP13300R is a 3-pole Type MCP motor circuit protector with a 600VAC rating, operating solely on a magnetic principle and with an instantaneous trip range of 100 to 300 amps; it comes with standard aluminum alloy terminals, giving you one more specific point to compare it with the protector you are replacing.
Key Features and Benefits
- For the 30A, 3-pole configuration: clear electrical specifications let you compare the MCP13300R with an existing motor circuit protector.
- The provided specifications describe this type of MCP protector as a magnetic-only type.
- The instantaneous trip range is clear enough for technicians to check when assessing application requirements.
- The rating is 600 VAC, as stated in the provided product information.
- The standard aluminum alloy terminals are provided, so the terminal material is included in the compatibility check during replacement.
Technical Specifications
-
Part Number: MCP13300R
-
Product Type: Motor Circuit Protector
-
Subcategory: Motor Circuit Protector
-
Type: MCP
-
Amperes: 30A
-
Poles: 3
-
Voltage Rating: 600VAC
-
Trip Type: Magnetic Only
-
Trip Function: Instantaneous Setting
-
Instantaneous Trip Range: 100–300A
-
Terminals: Standard Aluminum Alloy Terminals Included
-
Height: 6.0 in.
-
Width: 4.13 in.
-
Depth: 3.38 in.
-
Dimensions: 4.13"W x 6.00"H x 3.38"D
-
Approx. Shipping Weight: 6.50 lbs.
Material Compliance and Certifications
The available specifications indicate that the MCP13300R has standard aluminum alloy terminals; since no further information on terminal composition, conductor range, or materials used is provided, it would be wrong to assume anything about these features.
Where It Works Best
The MCP13300R motor circuit protector is a suitable replacement for existing or older electrical equipment that requires a 30A, 3-pole Type MCP protector with magnetic-only operation and an instantaneous trip current range of 100 to 300A; the application must match the 600VAC rating and the requirement for standard aluminum alloy terminals.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.