EATON
LDC3350 - 350 Amp Circuit Breaker
LDC3350 - 350 Amp Circuit Breaker
Couldn't load pickup availability
LDC3350 - 350 Amp Circuit Breaker
With the LDC3350, it’s worth looking beyond the 350A rating. Put all of that together—the LDC type, amperage, poles, trip configuration, terminals, ratings, and footprint—and you have a much clearer way to judge form, fit, and functional compatibility. When correctly matched, installed, and maintained within its stated ratings, the LDC3350 is built to last.
Key Features and Benefits
- 350A, three-pole configuration: One of the first details to check when comparing the LDC3350 with the breaker being replaced.
- Type LDC: Helps narrow the match when the existing equipment calls for this specific breaker type.
- Interchangeable trip unit: An important part of the LDC3350 configuration and something that should be included in the compatibility check.
- Thermal-magnetic design: Matches applications requiring the specified thermal-magnetic breaker arrangement.
- Load terminals included: You know the supplied load-side connection arrangement before installation.
- 40°C rated: Another specification to compare against the requirements of the existing equipment.
- HACR rated: A documented rating for applications where HACR suitability is required.
Technical Specifications
-
Part Number: LDC3350
-
Product Type: Circuit Breaker
-
Type: LDC
-
Amperage: 350A
-
Poles: 3
-
Protection Type: Thermal-Magnetic
-
Trip Unit: Interchangeable
-
A.I.C. at 240VAC: 200 kA
-
A.I.C. at 480VAC: 100 kA
-
A.I.C. at 600VAC: 50 kA
-
Temperature Rating: 40°C
-
HACR Rated: Yes
-
Load Terminals: Included
-
Width: 8.25 in.
-
Height: 10.75 in.
-
Depth: 4.06 in.
-
Overall Dimensions: 8.25" W × 10.75" H × 4.06"D
-
Approximate Shipping Weight: 24.00 lbs.
Material Compliance and Certifications
The information supplied for the LDC3350 identifies it as HACR-rated.
Where It Works Best
The LDC3350 350A 3-pole circuit breaker is best suited to compatible existing and legacy electrical equipment that calls for a Type LDC thermal-magnetic breaker with an interchangeable trip unit. Also check the included load terminals.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Share