EATON
LD3600L - 600Amp Circuit Breaker
LD3600L - 600Amp Circuit Breaker
Couldn't load pickup availability
LD3600L - 600Amp Circuit Breaker
The LD3600L is a 600-amp, 3-pole Type LD thermal-magnetic circuit breaker with an interchangeable trip unit. It's a solid fit for maintenance and replacement jobs where your existing equipment was designed around this particular LD breaker configuration. When the catalog number, ratings, trip configuration, connections, and physical fit match the application, the LD3600L provides the form, fit, and function needed to keep compatible equipment in service. Properly selected, installed, and used within its specified ratings, it is built to last in its intended application.
Key Features and Benefits
- 600A, 3-pole Type LD configuration
- Thermal-magnetic operation
- Interchangeable trip unit
- 40°C rated
- Line and load terminals included
- Defined dimensions make it easier to check physical compatibility
Technical Specifications
-
Part Number: LD3600L
-
Type: LD
-
Amperage: 600A
-
Poles: 3
-
Breaker Type: Thermal-magnetic
-
Trip Unit: Interchangeable
-
AIC Rating at 600VAC: 25kA
-
AIC Rating at 480VAC: 35kA
-
AIC Rating at 240VAC: 65kA
-
Temperature Rating: 40°C
-
HACR Rated: Yes
-
Terminals: Line and load terminals included
-
Height: 10.75 in.
-
Width: 8.25 in.
-
Depth: 4.06 in.
-
Dimensions: 8.25"W x 10.75"H x 4.06"D
-
Approximate Ship Weight: 24 lbs.
Material Compliance and Certifications
The supplied product information identifies the LD3600L as HACR rated. No specific UL, CSA, IEC, RoHS, REACH, or other certification or material-compliance information was provided, so do not assume those details.
Where It Works Best
The LD3600L is most relevant when you're working on existing or legacy equipment that specifically requires a 600A, 3-pole Type LD breaker. Rather than choosing a replacement based on amperage alone, compare the full set of specifications with what's already installed.
Start with the system voltage. The corresponding interrupting rating is 25 kA at 600 VAC, 35 kA at 480 VAC, and 65 kA at 240 VAC. The required AIC must match the electrical system.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Share