Skip to product information
1 of 1

CUTLER HAMMER

LCG3600F - 600Amp Max. *Frame ONLY*

LCG3600F - 600Amp Max. *Frame ONLY*

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

LCG3600F - 600Amp Max. *Frame ONLY*

The LCG3600F is a 600-amp, 3-pole Type LCG thermal-magnetic circuit breaker frame rated for 40°C applications and equipped with ground-fault circuit interruption. If you're sourcing this part for equipment already in service, pay close attention to the full specification, not just the amperage. For compatible existing and legacy equipment requiring this exact Type LCG configuration, it can serve as a form, fit, and functional replacement when all electrical and mechanical requirements align.

Key Features and Benefits

  • 600A, 3-pole configuration for equipment requiring these specific ratings
  • Type LCG thermal-magnetic circuit breaker frame
  • Specified with ground-fault circuit interruption
  • Rated for 40°C applications
  • Supplied as FRAME ONLY, helping buyers distinguish it from a complete breaker assembly

Technical Specifications

  • Part Number: LCG3600F
  • Type: LCG
  • Configuration: Frame Only
  • Circuit Breaker Type: Thermal Magnetic
  • Ground Fault: Ground Fault Circuit Interruption specified
  • Amperage: 600A
  • Poles: 3
  • Temperature Rating: 40°C
  • AIC at 600VAC: 35kA
  • AIC at 480VAC: 65kA
  • AIC at 240VAC: 100kA
  • Dimensions: 8.25"W x 10.75"L x 4.00"D
  • Width: 8.25 in.
  • Height/Length: 10.75 in.
  • Depth: 4.00 in.
  • Approximate Ship Weight: 25.00 lbs.

Material Compliance and Certifications

No specific UL, CSA, IEC, RoHS, REACH, or other certification or material-compliance information was supplied for the LCG3600F. Don't assume these details from the part number, Type LCG designation, or electrical ratings.

Where It Works Best

The LCG3600F is intended for compatible existing or legacy equipment that requires a 600A, 3-pole Type LCG frame with the supplied thermal-magnetic and ground-fault specifications.

For a replacement, compare the electrical ratings first. Make sure the application calls for 600 amps and three poles, then verify the required voltage and interrupting capacity against the LCG3600F's 35kA at 600VAC, 65kA at 480VAC, and 100kA at 240VAC ratings.


Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.

View full details