SQUARE D
LAL3640036M - 400 Amp Motor Circuit Protector
LAL3640036M - 400 Amp Motor Circuit Protector
Couldn't load pickup availability
LAL3640036M - 400 Amp Motor Circuit Protector
If you're matching a motor circuit protector in an existing LA installation, the LAL3640036M gives you several concrete specifications to work from. It's a 400A, 3-pole motor circuit protector rated for 600VAC, with a unit-mount design and lugs on both the line and load sides. The manufacturer describes this LA Mag-Gard device as magnetic-only, providing short-circuit protection and serving as a disconnect when used with a motor starter. When the electrical characteristics, protection scheme, connections, mounting, and dimensions all match—and the protector is properly installed and adjusted for the application.
Key Features and Benefits
- 400A rated current and 3-pole configuration
- Rated for 600VAC
- Manufacturer-described magnetic-only motor circuit protector
- Provides short-circuit protection only
- Designed for use as a disconnect in combination with motor starters
- Adjustable magnetic pickup allows the instantaneous opening point to be coordinated with the motor application
- 2,000A magnetic hold current
- 4,000A magnetic tripping current
- Unit-mount design
- Lugs on both the line and load sides
- Uses AL400LA terminals
Technical Specifications
-
Catalog Number: LAL3640036M
-
Product Type: Motor Circuit Protector
-
Series / Type: LA
-
Rated Current: 400A
-
Poles: 3
-
Voltage Rating: 600VAC
-
Protection: Magnetic-only, short-circuit protection
-
Magnetic Hold Current: 2,000A
-
Magnetic Tripping Current: 4,000A
-
Magnetic Pickup: Adjustable
-
Mounting: Unit mount
-
Connections: Line and load lugs
-
Terminal Identifier: AL400LA
-
Tightening Torque: 115.06 lbf-in (13 N·m), for the applicable specified conductor range
-
Specified Conductor Ranges: 1 AWG–600 kcmil and 1 AWG–250 kcmil, as applicable
-
Height: 11 in. (279.4 mm)
-
Width: 6 in. (152.4 mm)
-
Depth: 5.84 in. (148.34 mm)
-
Country of Origin: Mexico
Material Compliance and Certifications
- UL Listed
- CSA
- IEC
Where It Works Best
The LAL3640036M makes the most sense when you're working with existing or legacy motor-control equipment that calls for a 400A, 3-pole, 600VAC LA magnetic motor circuit protector in a unit-mount configuration.
Work through the match carefully. Check the 400A current rating and three-pole arrangement, then the 600VAC rating. Review the magnetic characteristics—2,000A hold and 4,000A trip—and make sure the adjustable pickup matches the motor application.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Square D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are NOT supplied by Schneider Electric or its affiliates.