SQUARE D
KHL36090 - 90 Amp Circuit Breaker
KHL36090 - 90 Amp Circuit Breaker
Couldn't load pickup availability
KHL36090 - 90 Amp Circuit Breaker
When you're tracking down a KHL36090, the 90-amp rating is an obvious place to start, but it isn't the only detail worth checking. This 3-pole Type KHL molded-case circuit breaker has a thermal-magnetic configuration, operates at 60Hz, and has a 40°C temperature rating. That's especially important with older or legacy systems, where a familiar-looking breaker isn't necessarily the right match. When the part number, ratings, dimensions, poles, and connection requirements align, the KHL36090 may provide the form, fit, and function needed for the application.
Key Features and Benefits
- 90A, 3-pole configuration for equipment requiring this specific breaker arrangement.
- Type KHL molded case circuit breaker with a thermal-magnetic configuration.
- Line and load lugs included, giving you an important connection detail to check against the existing installation.
- Specified for 60Hz operation and 40°C.
- Well suited to compatible existing and legacy equipment when the KHL36090's complete specifications match the application.
Technical Specifications
-
Part Number: KHL36090
-
Breaker Type: Molded Case Circuit Breaker
-
Type: KHL
-
Configuration: Thermal Magnetic
-
Amperage: 90A
-
Poles: 3
-
Frequency: 60Hz
-
Temperature Specification: 40°C
-
AIC at 600VAC: 25k
-
AIC at 480VAC: 35k
-
AIC at 240VAC: 65k
-
Lugs: Line and Load Lugs Included
-
Width: 4.50 in.
-
Height/Length: 8.00 in.
-
Depth: 3.69 in.
-
Dimensions: 4.50"W x 8.00"L x 3.69"D
-
Approx. Shipping Weight: 10.00 lbs.
Material Compliance and Certifications
No specific certification or material-compliance information was provided for the KHL36090. For that reason, UL status, RoHS, REACH, or other certifications and standards shouldn't be assumed.
Where It Works Best
The KHL36090 makes the most sense when you're servicing existing or legacy electrical equipment that calls for this particular Type KHL, 90-amp, 3-pole configuration.
Before installation, compare more than the catalog number. Check the 90A rating, three poles, thermal magnetic configuration, 60Hz frequency, 40°C specification, line and load lug requirements, and the 4.50"W x 8.00"L x 3.69"D dimensions. You'll also want to match the appropriate interrupting rating to the system voltage—25k AIC at 600VAC, 35k AIC at 480VAC, or 65k AIC at 240VAC.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Square D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are NOT supplied by Schneider Electric or its affiliates.
Share