SQUARE D
KHL36080 - 80 Amp Circuit Breaker
KHL36080 - 80 Amp Circuit Breaker
Couldn't load pickup availability
KHL36080 - 80 Amp Circuit Breaker
If you're replacing a KHL36080 in existing equipment, there are several details worth checking before the breaker goes in. This 80-amp, 3-pole Type KHL molded-case circuit breaker has a thermal-magnetic configuration and comes with line and load lugs. Check the KHL type, amperage, poles, physical size, lugs, and AIC rating for your system voltage against those of the breaker being replaced and the equipment requirements. If those specifications line up, the KHL36080 may be a good fit for the required form and function.
Key Features and Benefits
- 80A, 3-pole configuration for equipment requiring these specific electrical characteristics.
- The KHL molded-case design gives you another important identifier to check when matching an existing breaker.
- Thermal-magnetic configuration as specified for the KHL36080.
- Line and load lugs included so that this connection detail can be compared directly with the existing installation.
- Specified for 60Hz and 40°C.
- Well suited to compatible existing and legacy equipment where the KHL36080's form, fit, and ratings are required.
Technical Specifications
-
Part Number: KHL36080
-
Breaker Type: Molded Case Circuit Breaker
-
Type: KHL
-
Trip Configuration: Thermal Magnetic
-
Amperage: 80A
-
Poles: 3
-
Frequency: 60Hz
-
Temperature Specification: 40°C
-
AIC at 600VAC: 25k
-
AIC at 480VAC: 35k
-
AIC at 240VAC: 65k
-
Lugs: Line and Load Lugs Included
-
Width: 4.50 in.
-
Height/Length: 8.00 in.
-
Depth: 3.69 in.
-
Dimensions: 4.50"W x 8.00"L x 3.69"D
-
Approx. Shipping Weight: 10.00 lbs.
Material Compliance and Certifications
No specific material-compliance or certification information was included in the supplied specifications for the KHL36080. For that reason, certifications or listings such as UL, RoHS, REACH, or others shouldn't be assumed.
Where It Works Best
The KHL36080 makes the most sense in existing or legacy electrical equipment that calls for its particular Type KHL, 80A, 3-pole configuration.
Before using it as a replacement, compare it with the breaker already installed. Check the part number, breaker type, amperage, poles, dimensions, line and load lugs, 60Hz frequency, and 40°C specification. You'll also want to match the interrupting rating to the system voltage: 25k AIC at 600VAC, 35k AIC at 480VAC, or 65k AIC at 240VAC.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Square D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are NOT supplied by Schneider Electric or its affiliates.