Littelfuse

JTD400 - 400 Amp Fuse

JTD400 - 400 Amp Fuse

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

JTD400 - 400 Amp Fuse

A 400A rating is only the first thing to check when you're replacing a fuse. The JTD400 is a 400-amp Class J time-delay fuse with knife-blade construction, designed to meet specific electrical and physical requirements. It carries maximum voltage ratings of 600VAC and 500VDC and uses a Slo-Blo/Time Lag (T)/Time Delay opening characteristic. When matching a JTD400 replacement, check the full specification, not just amperage: fuse class, opening characteristic, AC or DC voltage, interrupting requirements, knife-blade construction, mounting, and non-indicating configuration all matter.

Key Features and Benefits

  • 400A continuous current rating for equipment specifically requiring a 400-amp fuse
  • Class J fuse configuration provides a clear specification to match against the equipment requirements
  • Time-delay opening characteristic, identified as Slo-Blo/Time Lag (T)/Time Delay
  • Maximum voltage rating of 600VAC
  • Also rated for a maximum of 500VDC
  • Knife-blade construction provides an important physical characteristic for replacement matching
  • Non-indicating design for equipment requiring this configuration
  • Part of the JTD Series
  • Identified as part of the POWR-PRO Fuse family
  • Designed for mounting in an appropriate fuse block, clip, or holder
  • LFJ60400 Series is specified as the PG holder

Technical Specifications

  • Catalog Number: JTD400
  • Series: JTD
  • Manufacturer Description: FUS 600V T/D CLASS J 400A
  • Product Type: Class J Time-Delay Fuse
  • Continuous Current Rating: 400A
  • Maximum AC Voltage: 600VAC
  • Maximum DC Voltage: 500VDC
  • AC Interrupting Value 1: 200,000A at 600VAC
  • AC Interrupting Value 2: 300,000A at 600VAC
  • DC Interrupting Rating: 20,000A at 500VDC
  • Published Interrupting Rating: 20 kA at 500VDC
  • Opening Characteristic: Slo-Blo / Time Lag (T) / Time Delay
  • Fuse Class: Class J
  • Family Style: POWR-PRO Fuse
  • Construction / Size: Knife-Blade
  • Indicating: No
  • Mounting Method: Fuse Block / Clip / Holder
  • Specified PG Holder: LFJ60400 Series

Material Compliance and Certifications

The supplied product information confirms the JTD400 electrical ratings, Class J designation, time-delay opening characteristic, knife-blade construction, non-indicating configuration, mounting method, and specified holder series.

Where It Works Best

The JTD400 400A Class J time-delay fuse is best suited to electrical equipment specifically designed for a 400A Class J, non-indicating, knife-blade fuse with corresponding time-delay characteristics. For AC service, verify the equipment requirements against the 600VAC maximum rating and the applicable manufacturer-supplied AC interrupting value. For DC service, confirm compatibility with the 500VDC maximum voltage and 20 kA interrupting rating at 500VDC.


Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Littelfuse® is a registered trademark of Littelfuse, Inc. Products sold are surplus, used, or refurbished and are NOT supplied by Littelfuse, Inc. or its affiliates.