Littelfuse

JTD350 - 350 Amp Fuse

JTD350 - 350 Amp Fuse

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

JTD350 - 350 Amp Fuse

A 350-amp rating may be the first thing you notice on the JTD350, but choosing the correct replacement means checking the whole specification. The JTD350 is a 350A Class J time-delay fuse with knife-blade construction and Slo-Blo/Time Lag (T)/Time Delay operation. Part of the JTD Series and POWR-PRO Fuse family, it carries maximum voltage ratings of 600VAC and 500VDC. When you're matching a JTD350 to existing equipment, don't stop at amperage: verify Class J requirements, time-delay operation, AC or DC voltage, applicable interrupting rating, knife-blade construction, non-indicating configuration, and holder compatibility.

Key Features and Benefits

  • 350A continuous current rating for equipment specifically requiring a 350-amp fuse
  • Class J fuse configuration for installations designed around this fuse class
  • Time-delay operation specified as Slo-Blo/Time Lag (T)/Time Delay
  • Maximum voltage rating of 600VAC
  • Supports equipment requirements up to a maximum of 500VDC
  • Knife-blade construction provides a clear physical characteristic to check when identifying a replacement
  • Part of the JTD Series
  • POWR-PRO Fuse family style
  • Non-indicating design
  • Compatible mounting method includes a fuse block, clip, or holder
  • LFJ60400 Series is the specified PG holder family

Technical Specifications

  • Catalog Number: JTD350
  • Series: JTD
  • Manufacturer Description: FUS 600V T/D CLASS J 350A
  • Product Type: Class J Time-Delay Fuse
  • Continuous Current Rating: 350A
  • Maximum AC Voltage: 600VAC
  • Maximum DC Voltage: 500VDC
  • AC Interrupting Value 1: 200,000A at 600VAC
  • AC Interrupting Value 2: 300,000A at 600VAC
  • DC Interrupting Rating: 20,000A at 500VDC
  • Published Interrupting Rating: 20 kA at 500VDC
  • Opening Characteristic: Slo-Blo / Time Lag (T) / Time Delay
  • Fuse Class: Class J
  • Family Style: POWR-PRO Fuse
  • Construction / Size: Knife-Blade
  • Indicating: No
  • Mounting Method: Fuse Block / Clip / Holder
  • Specified PG Holder: LFJ60400 Series

Material Compliance and Certifications

The supplied product information confirms the JTD350's Class J designation, 350A continuous current rating, time-delay opening characteristic, 600VAC and 500VDC maximum ratings, interrupting values, knife-blade construction, non-indicating configuration, and mounting information.

Where It Works Best

The JTD350 350A Class J time-delay fuse suits electrical equipment designed for a 350A, Class J, non-indicating, time-delay fuse with matching electrical and physical requirements. For AC service, verify the equipment requirements against the 600VAC maximum rating and the applicable manufacturer-supplied AC interrupting value. For DC service, confirm compatibility with the 500VDC maximum rating and 20 kA interrupting rating at 500VDC.


Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Littelfuse® is a registered trademark of Littelfuse, Inc. Products sold are surplus, used, or refurbished and are NOT supplied by Littelfuse, Inc. or its affiliates.

View full details