Littelfuse

JTD070-ID - 70 Amp Fuse

JTD070-ID - 70 Amp Fuse

Regular price $0.00 USD
Regular price Sale price $0.00 USD
Sale Sold out
Shipping calculated at checkout.
Condition

JTD070-ID - 70 Amp Fuse

When your replacement calls for an indicating 70A Class J time-delay fuse, matching the complete specification matters—not just the amp rating. The JTD070-ID, manufacturer catalog reference JTD070ID, is a 70-amp Class J fuse with Slo-Blo/Time Lag (T)/Time Delay operation and a knife-blade construction. For a proper replacement match, confirm the Class J designation, 70A rating, time-delay characteristic, voltage requirements, applicable interrupting rating, indicating design, knife-blade format, and mounting requirements.

Key Features and Benefits

  • 70A continuous current rating for equipment specified for a 70-amp fuse
  • Class J classification provides an essential reference point when matching a replacement
  • Time-delay opening characteristic specified as Slo-Blo/Time Lag (T)/Time Delay
  • Indicating design distinguishes the JTD070-ID from non-indicating configurations
  • Maximum 600VAC rating
  • Maximum 300VDC rating
  • Knife-blade construction gives you another critical physical detail to verify for compatibility.
  • Part of the JTD_ID Series
  • Identified as a POWR-PRO Fuse
  • Designed for mounting in a compatible fuse block, clip, or holder
  • LFJ60100 Series identified as the specified holder family

Technical Specifications

  • Catalog Number: JTD070-ID
  • Manufacturer Catalog Reference: JTD070ID
  • Series: JTD_ID
  • Product Type: Class J Time-Delay Indicating Fuse
  • Continuous Current Rating: 70A
  • Fuse Class: Class J
  • Opening Characteristic: Slo-Blo / Time Lag (T) / Time Delay
  • Maximum AC Voltage: 600VAC
  • Maximum DC Voltage: 300VDC
  • AC Interrupting Value 1: 200,000A at 600VAC
  • AC Interrupting Value 2: 300,000A at 600VAC
  • DC Interrupting Rating: 20,000A at 300VDC
  • Published Interrupting Rating: 20 kA at 300VDC
  • Size / Construction: Knife-Blade
  • Family Style: POWR-PRO Fuse
  • Indicating: Yes
  • Mounting Method: Fuse Block / Clip / Holder
  • Specified Holder Series: LFJ60100 Series

Material Compliance and Certifications

The supplied manufacturer specifications establish the JTD070-ID's Class J designation, 70A continuous current rating, time-delay opening characteristic, 600VAC and 300VDC maximum voltage ratings, interrupting values, knife-blade construction, indicating status, mounting method, and specified holder family.

Where It Works Best

The JTD070-ID 70A Class J time-delay indicating fuse suits electrical equipment designed for a 70A Class J fuse with time-delay operation and an indicating configuration. For AC installations, compare the equipment requirements with the fuse's 600VAC maximum rating and the applicable AC interrupting requirement. For DC service, the supplied specifications identify a 300VDC maximum rating and a 20 kA interrupting rating at 300VDC.


Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Littelfuse® is a registered trademark of Littelfuse, Inc. Products sold are surplus, used, or refurbished and are NOT supplied by Littelfuse, Inc. or its affiliates.

View full details