EATON
JKS-125 - 125 Amp Fuse
JKS-125 - 125 Amp Fuse
Couldn't load pickup availability
JKS-125 - 125 Amp Fuse
The Eaton Bussmann JKS-125 series is perfect for replacing fuses in electrical systems. Rated at 125 amps and 600 volts, this Class J fuse features a 200 kAIC interrupting rating at 600VAC and a bolted blade-end connection.
It's RoHS-compliant, making it a reliable choice for facilities needing this specific configuration. Just remember, successful use depends on ensuring the fuse specs match your equipment's requirements for optimal performance!
Key Features and Benefits
- 125A amperage rating: Provides the specified 125-amp rating for compatible equipment requiring a JKS-125 fuse.
- 600V rating: Designed for applications requiring a fuse with a manufacturer-specified 600-volt rating.
- Class J configuration: Clearly identified as a Class J fuse, an essential detail when confirming the correct fuse type.
- Bolted blade ends: Uses a bolted blade-end x bolted blade-end connection rather than leaving the connection style open to assumption.
- Single-element design: Manufacturer specifications identify the JKS-125 as a single-element fuse.
- Non-indicating: There is no built-in visual fuse-status indication.
Technical Specifications
-
Product Name: Eaton Bussmann series JKS fuse
-
Catalog Number: JKS-125
-
Product Type: Fuse
-
Fuse Class: Class J
-
Amperage Rating: 125A
-
Voltage Rating: 600V
-
Interrupting Rating: 200 kAIC at 600VAC
-
Number of Elements: 1
-
Connection: Bolted blade end x bolted blade end
-
Fuse Indicator: Non-indicating
-
Special Feature: Non-indicating
-
Product Length / Depth: 5.75 in
-
Product Height: 1.5 in
-
Product Width: 1.5 in
-
Product Weight: 0.855 lb
-
UPC: 051712631259
Material Compliance and Certifications
The manufacturer specifications provided for the JKS-125 fuse identify the following material compliance:
- RoHS Compliant
Where It Works Best
The JKS-125 125A 600V Class J fuse is best considered for compatible existing electrical equipment that specifically requires its combination of 125A amperage, 600V rating, Class J configuration, 200 kAIC interrupting rating at 600VAC, single-element construction, bolted blade connections, and corresponding physical dimensions. Its detailed specifications make it straightforward to compare the fuse with equipment documentation or an existing JKS-125 during maintenance and replacement work.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.