Skip to product information
1 of 1

SQUARE D

JGA36175 - 175 Amp Circuit Breaker

JGA36175 - 175 Amp Circuit Breaker

Regular price $2,325.71 USD
Regular price Sale price $2,325.71 USD
Sale Sold out
Shipping calculated at checkout.
Condition

JGA36175 - 175 Amp Circuit Breaker

A 175A rating alone isn't enough to identify the right breaker for an existing installation. With the JGA36175, you also have an I-Line connection on the line side, mechanical lugs on the load side, three poles, and a PowerPacT J-Frame design for comparison with the equipment already in place. The JGA36175 is built to last and is a practical choice when these electrical, connection, and dimensional requirements line up with the distribution equipment already in service.

Key Features and Benefits

  • 175A, 3-pole J-Frame design: Provides the core identifiers needed when checking a replacement against existing equipment.
  • Thermal-magnetic protection: Provides overload and short-circuit protection using the specified trip technology.
  • I-Line line-side connection: The line side uses an I-Line connection, while the load side uses mechanical lugs.
  • AL175JD terminal: Accepts 4 AWG through 4/0 AWG aluminum or copper conductors.
  • Adjustable long-time pickup: Adjustment range is 0.25–1 × In.
  • Push-to-trip button: An integral button allows the breaker to be manually tripped.
  • 80% continuous-current rating: Gives you another specific value to confirm against the installation requirements.

Technical Specifications

  • Catalog Number: JGA36175
  • Product Family: PowerPacT J
  • Product Type: Circuit breaker
  • Application: Distribution
  • Frame: J-Frame
  • Rated Current: 175A
  • Poles: 3
  • Trip Technology: Thermal-magnetic
  • Protection Type: Overload and short-circuit
  • Control: Toggle
  • Breaking Capacity Code: G
  • Breaking Capacity at 240VAC: 65 kA, 50/60 Hz, UL 489
  • Breaking Capacity at 480VAC: 35 kA, 50/60 Hz, UL 489
  • Breaking Capacity at 600VAC: 18 kA, 50/60 Hz, UL 489
  • Breaking Capacity at 250VDC: 18 kA, UL 489
  • Breaking Capacity at 500VDC: 20 kA, UL 489
  • Rated Operational Voltage: 600VAC, 50/60 Hz, IEC 60947-3
  • Line-Side Connection: I-Line
  • Load-Side Connection: Lugs
  • Height: 7.5 in. (191 mm)
  • Width: 4.09 in. (104 mm)
  • Depth: 3.4 in. (86 mm)
  • HACR Rated: Yes

Material Compliance and Certifications

The JGA36175 carries a CE quality label and is listed with UL, CSA, and NOM product certifications. The manufacturer also identifies UL, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 among the applicable standards. The front cover has an IP40 rating and a pollution degree of 3, as specified in IEC 60947-1.

Where It Works Best

The JGA36175 is intended for compatible distribution equipment that calls for a 175A, three-pole J-Frame breaker with I-Line construction. It's especially useful in replacement situations where the existing setup requires an I-Line line connection and load-side lugs rather than a different connection arrangement.


Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.

Square D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are NOT supplied by Schneider Electric or its affiliates.

View full details