The HGA36150 PowerPacT H circuit breaker is a 150-amp, 3-pole breaker built for your electrical distribution systems that need reliable thermal-magnetic protection. The breaker also uses dual-break rotating contacts to help reduce peak current during a short-circuit fault. A push-to-trip button is built into the cover, giving qualified technicians a simple way to manually trip the breaker when required. With a 150A rating, three poles, 80% continuous-current rating, ABC phase connection, HACR rating, and aluminum/copper conductor compatibility, the HGA36150 is a practical choice for replacement, maintenance, and distribution work where these exact specifications are needed.
Key Features and Benefits
- 150A, 3-pole design – Made for three-pole distribution applications that require a 150-amp breaker.
- Thermal-magnetic trip protection – Handles overload and short-circuit protection without an electronic trip unit.
- I-Line configuration – Designed for compatible I-Line equipment, with mechanical lugs on the load side.
- Dual-break rotating contacts – Helps limit peak current during short-circuit conditions.
- Push-to-trip button – Lets qualified personnel manually trip the breaker when needed.
- 80% continuous-current rating – Configured with an ABC phase connection.
-
Wide conductor range – AL150HD terminals accept 14 AWG through 3/0 AWG aluminum or copper conductors.
Technical Specifications
-
Catalog Number: HGA36150
-
Product Family: PowerPacT H
-
Product Type: Circuit Breaker
-
Rated Current: 150 A
-
Number of Poles: 3
-
Protected Poles: 3t
-
Trip Technology: Thermal-magnetic
-
Control Type: Toggle
-
Breaking Capacity at 240VAC: 65 kA, 50/60 Hz, UL 489
-
Breaking Capacity at 480VAC: 35 kA, 50/60 Hz, UL 489
-
Breaking Capacity at 600VAC: 18 kA, 50/60 Hz, UL 489
-
Breaking Capacity at 250VDC: 20 kA, UL 489
-
Breaking Capacity at 500VDC: 20 kA, UL 489
-
Rated Operational Voltage: 690VAC, 50/60 Hz, IEC 60947-3
-
Rated Insulation Voltage: 750 V
-
Impulse Withstand Voltage: 8 kV
-
Network Frequency: 50/60 Hz
-
Magnetic Tripping Current: 1700 A
-
Magnetic Hold Current: 900 A
-
Continuous Current Rating: 80%
-
Suitability for Isolation: Yes, IEC 60947-2
-
Utilization Category: Category A
-
Phase Connection: ABC
-
Mounting: I-Line bracket
-
Line-Side Connection: I-Line
-
Load-Side Connection: Mechanical lugs
-
Height: 6.4 in. (163 mm)
-
Width: 4.09 in. (104 mm)
-
Depth: 3.4 in. (86 mm)
-
Product Weight: 4.9 lb. (2.2 kg)
Material Compliance and Certifications
The HGA36150 carries UL, CSA, and NOM certifications and is CE marked. It also meets applicable UL, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 standards. The front cover is rated IP40 under IEC 60529, and the breaker is classified for Pollution Degree 3 under IEC 60947-1.
Where It Works Best
The HGA36150 is a good fit for commercial, industrial, institutional, and facility electrical systems that use compatible I-Line equipment. It is especially useful where the application calls for a 150A, 3-pole thermal-magnetic breaker with an 18 kA interrupting rating at 600VAC.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Square D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are NOT supplied by Schneider Electric or its affiliates.