SIEMENS
FXD62B090L - 90Amp Circuit Breaker
FXD62B090L - 90Amp Circuit Breaker
Couldn't load pickup availability
FXD62B090L - 90Amp Circuit Breaker
The FXD62B090L is a 90 Amp, 2-pole molded case circuit breaker used in electrical systems that require an FXD/FD frame breaker with factory-installed line and load lugs. It is commonly selected for commercial and industrial electrical equipment where maintaining the existing breaker specifications is important. When you're replacing a breaker in an established system, matching the frame style, amperage rating, voltage rating, trip characteristics, and terminal configuration helps keep the installation consistent with the original design.
Key Features and Benefits
- 90 Amp molded case circuit breaker
- Two-pole configuration for compatible electrical applications
- FXD/FD frame design
- Thermal-magnetic trip unit for overload and short-circuit protection
- Non-interchangeable trip unit
- Includes line and load side lugs
- Rated for systems up to 600VAC
- 22kAIC at 600VAC
- 35kAIC at 480VAC
- Standard 40°C breaker rating
- Supports copper and aluminum conductors
- Molded case construction built to last
- Helps maintain existing electrical equipment configuration
Technical Specifications
-
Catalog Number: FXD62B090L
-
Manufacturer Part Number: FXD62B090L
-
Product Type: Molded Case Circuit Breaker
-
Frame Type: FXD / FD Frame
-
Product Family: FD6, 22kAIC, 600VAC
-
Amperage Rating: 90 Amps
-
Poles: 2
-
Trip Type: Thermal-Magnetic
-
Trip Unit: Non-Interchangeable
-
Voltage Rating: 600VAC Maximum
-
Interrupting Ratings:
- 22kAIC @ 600VAC
- 35kAIC @ 480VAC
-
Temperature Rating: 40°C
-
Terminals: Line and Load Side Lugs Included
-
Lug Type: TA1FD350A
-
Wire Range:
- Copper: 6 AWG – 350 kcmil
- Aluminum: 4 AWG – 350 kcmil
-
Standards:
- UL 489
- IEC 60947-2
-
Dimensions: 4.50"W × 9.50"H × 4.00"D
-
Height: 9.5 in.
-
Width: 4.5 in.
-
Depth: 4.0 in.
-
Net Weight: 8.62 lbs.
Material Compliance and Certifications
The FXD62B090L is a molded case circuit breaker designed for use in compatible FD/FXD frame electrical distribution equipment. It meets applicable requirements under UL 489 and IEC 60947-2 standards. Installation should be performed by qualified electrical personnel and completed according to applicable electrical codes, safety practices, and equipment requirements.
Where It Works Best
- Commercial electrical distribution systems
- Industrial facilities
- Manufacturing plants
- Panelboards and switchboards
- Equipment designed for FD/FXD frame breakers
- Applications requiring factory-installed breaker lugs
- Electrical systems requiring a 90 Amp, 2-pole molded case circuit breaker
- Maintenance and repair projects involving existing electrical equipment
- Installations where preserving the original breaker configuration is important
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Siemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are NOT supplied by Siemens AG or its affiliates.
Share