Eaton
FRS-R-600 - 600 Amp Fuse
FRS-R-600 - 600 Amp Fuse
Couldn't load pickup availability
FRS-R-600 - 600 Amp Fuse
With a 600-amp fuse, matching the amperage is important—but it’s far from the only specification that matters. Whether you’re matching an existing FRS-R-600 fuse or checking equipment documentation, looking at the complete specification—fuse class, voltage, interrupt rating, connection style, and dimensions—provides a much better basis for determining compatibility than simply matching the 600A rating.
Key Features and Benefits
- 600A Class RK5 fuse: Combines the 600-amp rating with the specific Class RK5 designation for accurate product identification.
- Dual-element configuration: Matches equipment specifications that require this configuration.
- Defined response characteristic: The manufacturer specifies a 10-second response time at 500% of rated current.
- Blade connections: Use blade-end-to-blade-end connections, making the connection style straightforward to verify during replacement.
- Non-indicating design: Does not incorporate a built-in fuse-status indicator.
- CE Marked: CE marking is included in the supplied manufacturer specifications.
Technical Specifications
-
Product Name: Eaton Bussmann series FRS-R fuse
-
Catalog Number: FRS-R-600
-
UPC: 051712508568
-
Product Type: Fuse
-
Fuse Class: Class RK5
-
Amperage Rating: 600 A
-
Voltage Rating: 600 VAC, 300 VDC
-
Interrupt Rating at 600 VAC: 200 kAIC
-
Interrupt Rating at 300 VDC: 20 kAIC
-
Response Time: 10 sec at 500%
-
Number of Elements: Dual
-
Connection: Blade end x blade end
-
Fuse Indicator: Non-indicating
-
Length/Depth: 13.38 in
-
Height: 3.13 in
-
Width: 3.13 in
-
Product Weight: 0.001 lb*
-
Compliance: CE Marked
Material Compliance and Certifications
The supplied specifications identify the Eaton Bussmann FRS-R-600 as CE-marked. No additional certifications or specific material-compliance declarations were provided for this catalog number, so additional compliance claims are not being inferred.
Where It Works Best
The FRS-R-600 600A fuse is appropriate for compatible electrical equipment that specifically requires a Class RK5, dual-element fuse with blade connections and electrical ratings matching this model. It is especially straightforward to identify when FRS-R-600 is already specified in the equipment documentation or appears on the fuse being replaced.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.