When you're tracking down an FRN-R-80, getting the details right matters. This 80A Class RK5 fuse uses dual-element construction, blade terminals at both ends, and a non-indicating design. Physically, the fuse measures 5.88 inches long, 1 inch high, and 1 inch wide. That gives you a solid set of electrical and dimensional details to compare with the fuse holder and circuit requirements before installation.
Key Features and Benefits
- 80A Class RK5 rating with dual-element construction.
- Handles applications within its published 250V AC and 125V DC ratings.
- Eaton specifies a 10-second response at 500% of rated current.
- Blade end × blade end construction and a non-indicating design.
- Measures 5.88 × 1 × 1 in., an important check when confirming the intended fuse position.
Technical Specifications
-
Manufacturer Series: Eaton Bussmann Series FRN-R
-
Catalog Number: FRN-R-80
-
Product Type: Fuse
-
Amperage Rating: 80A
-
Class: Class RK5
-
Voltage Rating: 250V AC / 125V DC
-
Interrupting Rating: 200 kAIC at 250V AC; 20 kAIC at 125V DC
-
Response Time: 10 seconds at 500% of rated current
-
Number of Elements: Dual
-
Connection: Blade end × blade end
-
Fuse Indicator: Non-indicating
-
Length / Depth: 5.88 in
-
Height: 1 in
-
Width: 1 in
-
Product Weight: 0.3 lb
-
UPC: 051712507417
Material Compliance and Certifications
The FRN-R-80 is CE Marked, according to the manufacturer information supplied for this catalog number. No other catalog-specific certifications or material-compliance declarations were provided. Where a project calls for a particular certification or compliance document, verify that requirement separately before installation.
Where It Works Best
- Existing electrical equipment calling for an FRN-R-80 80A Class RK5 fuse.
- Class RK5 fuse positions requiring blade-to-blade connections and the stated dimensions of 5.88 × 1 × 1 in.
- 250V AC circuits where a 200 kAIC at 250V AC interrupting rating satisfies the circuit requirements.
- 125V DC circuits where the 20 kAIC at 125V DC rating and remaining FRN-R-80 specifications are appropriate.
- Maintenance work where the fuse class, amperage, voltage, connection style, dimensions, and interrupting rating have all been confirmed.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.