Littelfuse
FLSR070-ID - 70Amp Fuse
FLSR070-ID - 70Amp Fuse
Couldn't load pickup availability
FLSR070-ID - 70Amp Fuse
The FLSR070-ID is designed for your electrical systems that require 70A Class RK5 protection without treating every brief startup surge as a fault. Motors, transformers, and similar equipment can pull extra current when they're first energized. That's where the time-delay design comes in. The FLSR070-ID can handle appropriate short-duration inrush while still protecting against sustained overloads and short circuits.
Key Features and Benefits
- 70A continuous rating for circuits requiring 70-amp fuse protection.
- Class RK5 dual-element design provides time-delay operation along with overload and short-circuit protection.
- Handles applications rated up to 600 VAC or 300 VDC.
- The Slo-Blo / time-delay characteristic helps the fuse tolerate appropriate temporary startup and inrush current.
- Indicating design makes an open fuse easier to spot during maintenance and troubleshooting.
- Knife-blade construction is well-suited to applications designed for this style of industrial fuse.
- Designed for installation using the appropriate fuse block, clip, or holder.
- Specified for use with the LFR60100 Series PG holder.
Technical Specifications
-
Catalog Number: FLSR070-ID / FLSR070ID
-
Series: FLSR_ID
-
Fuse Class: Class RK5
-
Fuse Style: Dual Element Fuse
-
Current Rating: 70A continuous
-
Maximum AC Voltage: 600VAC
-
Maximum DC Voltage: 300VDC
-
Opening: Slo-Blo / Time Lag (T) / Time Delay
-
AC Interrupt Amperage: 200,000A at 600VAC
-
Additional Manufacturer-Specified AC Interrupt Amperage: 300,000A at 600VAC
-
DC Interrupting Rating: 20,000A at 300VDC
-
Construction: Knife-Blade
-
Indicating: Yes
-
Mounting: Fuse Block / Clip / Holder
-
PG Holder: LFR60100 Series
Material Compliance and Certifications
The FLSR070-ID is a Class RK5 fuse, but fuse class and amperage aren't the only details that matter when you're matching a fuse to a piece of equipment. The voltage rating, interrupting capacity, time-delay requirement, physical style, and equipment specifications need to line up as well.
If your application requires specific agency approvals or environmental and material compliance documentation, check the current documentation for the exact FLSR070ID catalog number. Requirements such as UL, CSA, RoHS, or REACH should be confirmed for this specific part rather than assumed based on other products in the same family.
Where It Works Best
This fuse is especially useful in circuits where a brief current surge is normal. A motor, for example, can draw considerably more current when it starts than when it's running. A transformer can also experience an initial inrush when energized. The FLSR070-ID's time-delay characteristic is intended to accommodate appropriate short-lived conditions like these while still responding when an overcurrent condition persists.
That makes the FLSR070-ID a potential fit for properly specified motor circuits, transformers, industrial machinery, motor-control equipment, feeders, switchboards, service equipment, and power-distribution systems requiring a 70A Class RK5 time-delay fuse.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Littelfuse® is a registered trademark of Littelfuse, Inc. Products sold are surplus, used, or refurbished and are NOT supplied by Littelfuse, Inc. or its affiliates.
Share