EATON
CH1060 - 60Amp Circuit Breaker
CH1060 - 60Amp Circuit Breaker
Couldn't load pickup availability
CH1060 - 60Amp Circuit Breaker
The CH1060 is a 60 amp, 1-pole bolt-on circuit breaker used in compatible CH-type panelboards and electrical distribution equipment. It's commonly found in commercial buildings, schools, healthcare facilities, warehouses, retail locations, and light industrial applications. When you're replacing an existing breaker, matching the original amperage rating, pole configuration, and mounting style is often important, and the CH1060 is designed for those types of installations.
This breaker features a thermal magnetic trip unit with a non-interchangeable trip design. Rated 14kA at 277VAC, it is frequently used on branch circuits serving HVAC equipment, refrigeration systems, lighting panels, control circuits, and general electrical distribution loads.
The CH1060 is HACR rated, operates on 50/60Hz electrical systems, and is designed for ambient temperatures up to 40°C. You'll find breakers like this throughout facilities where keeping existing CH equipment in service is part of the job. Built to last, the CH1060 provides the form, fit, and function required for compatible replacement and maintenance applications.
Key Features and Benefits
- 60 amp current rating
- Single-pole configuration
- Bolt-on mounting style
- Thermal magnetic trip unit
- Non-interchangeable trip design
- 14kA interrupting rating at 277VAC
- HACR rated
- Designed for 50/60Hz operation
- Suitable for branch circuit protection
- Compact footprint for panelboard installations
- Built to last
Technical Specifications
-
Part Number: CH1060
-
Type: CH
-
Circuit Breaker Type: Bolt-On Thermal Magnetic Circuit Breaker
-
Amperage Rating: 60 Amps
-
Poles: 1
-
Voltage Rating: 277VAC
-
A.I.C. Rating: 14kA @ 277VAC
-
Frequency: 50/60Hz
-
Operating Temperature: 40°C
-
Trip Unit: Non-Interchangeable
-
HACR Rated: Yes
- Height: 4.00 in.
- Width: 1.00 in.
- Depth: 2.63 in.
-
Approximate Dimensions: 1.00"W × 4.00"H × 2.63"D
-
Approximate Shipping Weight: 2.25 lbs.
Material Compliance and Certifications
- HACR Rated
- Thermal magnetic overcurrent protection design
- Suitable for operation on 50/60Hz electrical systems
- Intended for installation in accordance with applicable electrical codes and equipment requirements
Where It Works Best
The CH1060 is often used in panelboards serving HVAC systems, refrigeration equipment, lighting circuits, control panels, and general electrical distribution applications. Common installation locations include office buildings, schools, healthcare facilities, retail stores, warehouses, apartment complexes, and light industrial facilities.
Use of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. CIRCUIT BREAKER SUPERSTORE® is an independent reseller and is not an authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do not apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.
Eaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are NOT supplied by Eaton Corporation plc or its affiliates.
Share