{"product_id":"tr60r","title":"TR60R - 60Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eTR60R - 60 Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf you're protecting equipment that experiences regular startup surges, the TR60R gives you a little extra breathing room without sacrificing reliable circuit protection. This 60 Amp Class R time-delay fuse is commonly used in commercial and industrial electrical systems where motors, transformers, and HVAC equipment can briefly pull higher current during startup. Instead of opening too quickly during those short bursts, the TR60R is designed to tolerate temporary inrush current while still helping protect circuits from overloads and short circuits. That balance makes it a solid choice for facilities that want dependable protection and fewer unnecessary shutdowns. The current-limiting design also helps reduce the amount of fault current that can pass through the system during a fault condition, helping protect connected equipment from additional damage. With a 200 kA interrupting rating at 250VAC, the TR60R is built for applications where higher fault-current protection is important. Its cartridge-style construction keeps installation simple, and the compact size works well in many control panels, disconnects, and distribution systems. Whether you're replacing an existing fuse or maintaining industrial equipment, the TR60R is a practical option for protecting electrical systems and keeping them operating reliably.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 Amp Class R Fuse:\u003c\/strong\u003e Designed for commercial and industrial electrical systems requiring dependable overcurrent protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-Delay Design:\u003c\/strong\u003e Helps reduce nuisance openings caused by temporary startup and inrush currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles Startup Surges:\u003c\/strong\u003e Built to tolerate short bursts of higher current commonly found in motors, transformers, and HVAC equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent-Limiting Protection:\u003c\/strong\u003e Helps reduce fault damage by limiting the amount of fault current that can pass through the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Interrupting Rating:\u003c\/strong\u003e Rated at 200 kA @ 250 VAC for applications where higher fault-current protection is important.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCartridge-Style Construction:\u003c\/strong\u003e Allows for straightforward installation in many electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Works well in control panels, disconnects, and distribution systems where installation space may be limited.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Indicating Fuse Construction:\u003c\/strong\u003e Suitable for standard overcurrent protection applications without indication features.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e TR60R\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Class R Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e TR\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 60A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 250 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 200 kA @ 250 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Style:\u003c\/strong\u003e Cartridge\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Type:\u003c\/strong\u003e Time-Delay\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndication Type:\u003c\/strong\u003e Non-Indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent-Limiting:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 3.0 in.\u003c\/li\u003e\n\u003cli\u003eWidth: 0.81 in.\u003c\/li\u003e\n\u003cli\u003eDepth: 0.81 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShip Weight:\u003c\/strong\u003e N\/A\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Compliance:\u003c\/strong\u003e The TR60R is manufactured for use in overcurrent protection applications found in commercial and industrial electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Notice:\u003c\/strong\u003e Always verify compatibility with your equipment ratings and local electrical code requirements before installation.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe TR60R is commonly used in motor circuits, HVAC systems, industrial machinery, control panels, commercial electrical distribution equipment, transformer applications, and manufacturing facilities. For systems that experience temporary startup surges yet still require dependable overcurrent protection, the TR60R offers a reliable, easy-to-install solution.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eMersen® is a registered trademark of Mersen S.A. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Mersen S.A. or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"New In Box","offer_id":50459297382699,"sku":"TR60R","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459297415467,"sku":"TR60R  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/tr60r","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}