{"product_id":"shld69600nt","title":"SHLD69600NT - 600Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSHLD69600NT - 600Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFinding the right replacement breaker starts with matching the original equipment. The SHLD69600NT is a 600 amp, 3-pole molded case circuit breaker built on the SLD600A frame and equipped with a SHLD6-A thermal magnetic trip unit. It's intended as a form, fit, and functional replacement for compatible electrical distribution systems, making it a practical choice for maintenance, repairs, and ongoing support of existing equipment.\u003c\/p\u003e\n\u003cp\u003eWhat makes this breaker especially useful is its adjustable trip unit. Instead of being limited to fixed protection settings, qualified personnel can adjust the continuous current setting, long-time delay, instantaneous trip, short-time pickup, short-time delay, and short-time I²t pickup to coordinate with the needs of the electrical system. That flexibility can simplify system coordination while helping protect connected equipment from overloads and short circuits.\u003c\/p\u003e\n\u003cp\u003eWith interrupting ratings of 35kA at 600VAC, 65kA at 480VAC, and 100kA at 240VAC, the SHLD69600NT is commonly found in commercial buildings, industrial facilities, manufacturing plants, and other heavy-duty power distribution applications. It is built to last and should always be installed in equipment verified to be compatible with its ratings and frame size. Lug terminals are not included with this breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e600 Amp Current Rating:\u003c\/strong\u003e 600 amp current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Pole Molded Case Circuit Breaker:\u003c\/strong\u003e Three-pole molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Magnetic Protection:\u003c\/strong\u003e Thermal magnetic protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSHLD6-A Adjustable Trip Unit:\u003c\/strong\u003e SHLD6-A adjustable trip unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Functions Include:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous Current Setting\u003c\/li\u003e\n\u003cli\u003eLong Time Delay\u003c\/li\u003e\n\u003cli\u003eInstantaneous Setting\u003c\/li\u003e\n\u003cli\u003eShort Time Pickup\u003c\/li\u003e\n\u003cli\u003eShort Time Delay\u003c\/li\u003e\n\u003cli\u003eShort Time I²t Pickup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Ratings:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35kA @ 600VAC\u003c\/li\u003e\n\u003cli\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to Last:\u003c\/strong\u003e Built to last.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm, Fit, and Functional Replacement:\u003c\/strong\u003e Intended as a form, fit, and functional replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Lug terminals not included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SHLD69600NT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e SLD600A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SHLD6-A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e Molded Case\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 600 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35kA @ 600VAC\u003c\/li\u003e\n\u003cli\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 11.0 in.\u003c\/li\u003e\n\u003cli\u003eWidth: 7.5 in.\u003c\/li\u003e\n\u003cli\u003eDepth: 4.0 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Not Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing:\u003c\/strong\u003e This molded case circuit breaker is manufactured to its published electrical ratings for use in compatible electrical distribution equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Installation should be performed by qualified personnel in accordance with applicable electrical codes and manufacturer recommendations. Confirm compatibility, interrupting capacity, and application requirements before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe SHLD69600NT is often used in switchboards, panelboards, industrial machinery, manufacturing facilities, commercial buildings, and other power distribution equipment requiring a 600 amp, 3-pole thermal magnetic molded case circuit breaker. It is intended for compatible existing installations where maintaining the original equipment configuration is important.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503968788779,"sku":"SHLD69600NT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503968821547,"sku":"SHLD69600NT [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/shld69600nt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}