{"product_id":"shld69600ngt","title":"SHLD69600NGT - 600Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSHLD69600NGT - 600Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen your electrical system requires a 600 amp, 3-pole molded case circuit breaker that matches the form, fit, and function of your existing equipment, the SHLD69600NGT is designed to meet that need. Built on the SLD600A frame, this thermal magnetic breaker provides dependable overcurrent and short-circuit protection for commercial and industrial power distribution systems. Its adjustable electronic trip functions allow qualified personnel to fine-tune protection settings for the specific application, helping coordinate the breaker with the rest of the electrical system.\u003c\/p\u003e\n\u003cp\u003eWhether you're replacing a worn breaker during scheduled maintenance or keeping an existing installation operating as intended, the SHLD69600NGT is designed to integrate into compatible systems without unnecessary modifications. Its durable molded case construction is built to last, while the combination of thermal magnetic protection and multiple adjustable trip settings makes it suitable for a wide range of power distribution applications. Please note that lug terminals are not included and must be obtained separately if required for your installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e600 Amp Continuous Rating:\u003c\/strong\u003e Designed for high-capacity commercial and industrial electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Pole Configuration:\u003c\/strong\u003e Suitable for three-phase power applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Magnetic Protection:\u003c\/strong\u003e Helps protect equipment from overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLD600A Frame:\u003c\/strong\u003e Designed for compatibility with equipment using this frame size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Trip Unit:\u003c\/strong\u003e Configure protection settings to suit your application, including:\n\u003cul\u003e\n\u003cli\u003eContinuous Current Setting\u003c\/li\u003e\n\u003cli\u003eLong Time Delay\u003c\/li\u003e\n\u003cli\u003eInstantaneous Setting\u003c\/li\u003e\n\u003cli\u003eShort Time Pickup\u003c\/li\u003e\n\u003cli\u003eShort Time Delay\u003c\/li\u003e\n\u003cli\u003eShort Time I²t Pickup\u003c\/li\u003e\n\u003cli\u003eGround Fault Pickup\u003c\/li\u003e\n\u003cli\u003eGround Fault Delay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm, Fit, and Functional Replacement:\u003c\/strong\u003e Intended for compatible legacy electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to Last:\u003c\/strong\u003e Designed for long-term service in demanding electrical environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals Not Included:\u003c\/strong\u003e Terminal lugs must be supplied separately if needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SHLD69600NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SHLD6-A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e SLD600A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Breaker Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 600 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35kA @ 600VAC\u003c\/li\u003e\n\u003cli\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 11.0 in.\u003c\/li\u003e\n\u003cli\u003eWidth: 7.5 in.\u003c\/li\u003e\n\u003cli\u003eDepth: 4.0 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Not Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Molded case circuit breaker construction for commercial and industrial electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Mechanism:\u003c\/strong\u003e Thermal magnetic trip mechanism with adjustable protection functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Designed for installation in compatible equipment within its published electrical ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Always verify compatibility with your equipment and follow applicable national, state, and local electrical codes before installation.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe SHLD69600NGT is commonly used in switchboards, panelboards, motor control equipment, industrial facilities, manufacturing plants, commercial buildings, and other high-capacity electrical distribution systems that require a 600 amp, 3-pole molded case circuit breaker. It's especially well suited for maintenance and replacement projects where matching the original frame size, electrical ratings, and trip characteristics is important to maintaining the existing system configuration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503968690475,"sku":"SHLD69600NGT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503968723243,"sku":"SHLD69600NGT [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/shld69600ngt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}