{"product_id":"shjd69400","title":"SHJD69400 - 400Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSHJD69400 - 400Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SHJD69400 is a 400 amp, 3-pole molded case circuit breaker built on the SJD 400A frame and intended for use in compatible commercial and industrial electrical systems. It uses a thermal magnetic trip unit to provide protection against overloads and short circuits while allowing key trip settings to be adjusted for the application.\u003c\/p\u003e\n\u003cp\u003eUnlike breakers with fixed trip characteristics, this model lets qualified personnel adjust the continuous current setting, long-time delay, and instantaneous trip functions. That flexibility can make it easier to coordinate protection with other equipment already installed in the system. Its interrupting ratings of 35kA at 600VAC, 65kA at 480VAC, and 100kA at 240VAC make it suitable for a variety of distribution applications where those ratings are required.\u003c\/p\u003e\n\u003cp\u003eWhether you're replacing an existing breaker during maintenance or matching the specifications of original equipment, the SHJD69400 is intended as a form, fit, and functional replacement for compatible installations. It's built to last and fits applications where maintaining the existing electrical system is the goal. Lug terminals are not included, so they will need to be supplied separately if required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e400 Amp Current Rating:\u003c\/strong\u003e 400 Amp current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-Pole Configuration:\u003c\/strong\u003e Three-pole configuration for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Magnetic Trip Unit:\u003c\/strong\u003e Thermal magnetic trip unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSJD 400A Frame:\u003c\/strong\u003e SJD 400A frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Trip Functions Include:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous Current Setting\u003c\/li\u003e\n\u003cli\u003eLong Time Delay\u003c\/li\u003e\n\u003cli\u003eInstantaneous Setting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Ratings:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35kA @ 600VAC\u003c\/li\u003e\n\u003cli\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Compatibility:\u003c\/strong\u003e Form, fit, and functional replacement for compatible equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to Last:\u003c\/strong\u003e Built to last.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Lug terminals not included.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SHJD69400\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SHJD6-A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e SJD 400A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 400A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal Magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Functions:\u003c\/strong\u003e Continuous Current Setting, Long Time Delay, Instantaneous Setting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity:\u003c\/strong\u003e 35kA @ 600VAC; 65kA @ 480VAC; 100kA @ 240VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 11.0 in.\u003c\/li\u003e\n\u003cli\u003eWidth: 7.5 in.\u003c\/li\u003e\n\u003cli\u003eDepth: 4.0 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Not Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Molded case circuit breaker construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Thermal magnetic overcurrent protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Compatibility:\u003c\/strong\u003e Intended for installation in compatible electrical distribution equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility Verification:\u003c\/strong\u003e Verify compatibility with your existing equipment before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Installation should be completed by qualified personnel and in accordance with applicable electrical codes.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe SHJD69400 is commonly found in commercial buildings, manufacturing facilities, schools, healthcare facilities, and other locations that rely on medium-voltage power distribution equipment. It works well in compatible switchboards, panelboards, feeder circuits, and motor control applications where a 400 amp, 3-pole thermal magnetic breaker with adjustable trip settings matches the original system requirements. If you're maintaining an existing installation, this breaker provides the form, fit, and functional compatibility needed for many legacy electrical systems.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503966527787,"sku":"SHJD69400","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503966560555,"sku":"SHJD69400 [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/shjd69400","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}