{"product_id":"shjd69200g","title":"SHJD69200G - 200Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSHJD69200G - 200Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen you need a 200-amp molded-case breaker that meets the electrical requirements of your existing equipment, the SHJD69200G is designed to provide the form, fit, and function needed for compatible applications. Built on the SJD 400A frame, this 3-pole thermal magnetic circuit breaker helps protect electrical distribution systems from overloads and short circuits while offering adjustable trip settings that allow the breaker to be configured for your specific application. Whether it's installed in commercial facilities, industrial plants, or heavy-duty power distribution equipment, this breaker is built to last and deliver dependable circuit protection.\u003c\/p\u003e\n\u003cp\u003eOne of the standout features of the SHJD69200G is its adjustable trip unit, giving qualified personnel the flexibility to fine-tune protection settings for the electrical system. Adjustable functions include Continuous Current Setting, Long Time Delay, Instantaneous Setting, Ground Fault Pick Up, and Ground Fault Delay, allowing the breaker to match system requirements better while helping protect valuable equipment. With interrupting ratings of 35kA at 600VAC, 65kA at 480VAC, and 100kA at 240VAC, this breaker is intended for installations that require those electrical ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 Amp Current Rating:\u003c\/strong\u003e 200 Amp current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-Pole Configuration:\u003c\/strong\u003e 3-pole configuration for three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSJD 400A Frame:\u003c\/strong\u003e SJD 400A frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Magnetic Trip Mechanism:\u003c\/strong\u003e Thermal magnetic trip mechanism for overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Trip Unit:\u003c\/strong\u003e Includes:\n\u003cul\u003e\n\u003cli\u003eContinuous Current Setting\u003c\/li\u003e\n\u003cli\u003eLong Time Delay\u003c\/li\u003e\n\u003cli\u003eInstantaneous Setting\u003c\/li\u003e\n\u003cli\u003eGround Fault Pick Up\u003c\/li\u003e\n\u003cli\u003eGround Fault Delay\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Ratings:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e35kA @ 600VAC\u003c\/li\u003e\n\u003cli\u003e65kA @ 480VAC\u003c\/li\u003e\n\u003cli\u003e100kA @ 240VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm, Fit, and Functional Replacement:\u003c\/strong\u003e Designed as a form, fit, and functional replacement for compatible electrical systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt to Last:\u003c\/strong\u003e Built to last in demanding commercial and industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Lug terminals are not included.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SHJD69200G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SHJD6-A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e SJD 400A Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal Magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 200A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 35kA @ 600VAC; 65kA @ 480VAC; 100kA @ 240VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Functions:\u003c\/strong\u003e Continuous Current Setting, Long Time Delay, Instantaneous Setting, Ground Fault Pick Up, Ground Fault Delay\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 11.0 in.\u003c\/li\u003e\n\u003cli\u003eWidth: 7.5 in.\u003c\/li\u003e\n\u003cli\u003eDepth: 4.0 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Terminals:\u003c\/strong\u003e Not Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e The SHJD69200G is manufactured for use in commercial and industrial electrical distribution systems and is designed to meet the electrical ratings specified for this model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e Installation should always be performed by qualified personnel in accordance with applicable electrical codes, manufacturer recommendations, and local regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Before installation, verify compatibility with the existing equipment, including voltage, interrupting capacity, frame size, and application requirements.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe SHJD69200G is commonly used in switchboards, panelboards, motor control centers, industrial machinery, manufacturing facilities, commercial buildings, and other three-phase power distribution systems requiring a 200-amp molded-case circuit breaker. It's an ideal solution when replacing a compatible breaker in an existing system where maintaining the original form, fit, function, and electrical ratings is essential.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503965249835,"sku":"SHJD69200G","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503965282603,"sku":"SHJD69200G [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/shjd69200g","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}