{"product_id":"sclr110","title":"SCLR110 - 110 Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eSCLR110 - 110 Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen electrical equipment depends on proper overcurrent protection, choosing a fuse with the right ratings is essential. The Eaton Edison SCLR110 Fuse delivers 110 Amp, 600V AC protection in a fast-acting, current-limiting cartridge design. Its 200kA interrupting rating makes it suitable for compatible electrical systems where high available fault currents must be considered. Whether you're maintaining industrial machinery, servicing a commercial electrical installation, or replacing an existing SCLR110, this fuse combines the electrical ratings and physical specifications you need to choose confidently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e110 Amp Rating: Designed for circuits that require a 110A fuse.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Suitable for compatible AC electrical systems operating within its rated voltage.\u003c\/li\u003e\n\u003cli\u003eFast-Acting Operation: Responds to overcurrent conditions according to its specified time-current characteristics.\u003c\/li\u003e\n\u003cli\u003eClass RK1 Fuse: Provides a clear fuse classification to match equipment protection requirements.\u003c\/li\u003e\n\u003cli\u003eRejection-Style Design: Helps prevent certain incorrect fuse-class substitutions in compatible rejection-type fuseholders.\u003c\/li\u003e\n\u003cli\u003eNon-Indicating Type: Does not include an integrated blown-fuse indicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Series:\u003c\/strong\u003e Edison SCLR\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCLR110\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Cartridge Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Type:\u003c\/strong\u003e SCLR\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 110A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 200kAIC at 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Class:\u003c\/strong\u003e Class RK1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Characteristic:\u003c\/strong\u003e Fast-Acting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent-Limiting:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Feature:\u003c\/strong\u003e Rejection Style\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-Indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 9.63 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 1.79 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 1.79 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton Edison SCLR110 is part of the SCLR fuse family, which carries the following manufacturer-listed certifications and compliance markings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed: Listed to applicable UL safety requirements.\u003c\/li\u003e\n\u003cli\u003eCSA Certified: Certified to applicable CSA requirements.\u003c\/li\u003e\n\u003cli\u003eCE Marked: Carries the CE conformity marking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton Edison SCLR110 110A fuse may fit commercial and industrial equipment that requires fast-acting, current-limiting Class RK1 protection. Applications to consider include:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial Electrical Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommercial Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Fused Disconnect Switches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eManufacturing Facility Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Machinery Circuits\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFacility Electrical Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible 600V AC Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Control Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Panel Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquipment Short-Circuit Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDirect SCLR110 Fuse Replacement\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"New In Box","offer_id":50459283718443,"sku":"SCLR110","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459283751211,"sku":"SCLR110  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/sclr110","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}