{"product_id":"scld69600nt","title":"SCLD69600NT - 600Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69600NT - 600Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NT circuit breaker is a 600-amp, three-pole molded case circuit breaker (MCCB) from the Siemens SENTRON low-voltage product line. Designed for your electrical distribution equipment requiring an LD-frame breaker, this model combines a 600V AC voltage rating, current-limiting breaking-capacity construction, and a SensiTrip LSI electronic trip unit. It is rated 100kAIC at 600V AC and 150kAIC at 480V AC, giving electricians and maintenance professionals the electrical ratings needed to evaluate compatibility with existing commercial and industrial power distribution systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600-Amp Current Rating: Provides the specified current rating for compatible electrical distribution circuits requiring a 600A molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for electrical equipment requiring a three-pole breaker in a compatible three-phase distribution system.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Supports applications within the manufacturer's stated maximum AC voltage rating.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Construction: Features the frame configuration required for evaluating physical and functional compatibility with existing LD-frame installations.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Uses Siemens electronic trip technology with the LSI protection functions specified for this catalog number.\u003c\/li\u003e\n\u003cli\u003eLong-Time Protection: Addresses sustained overcurrent conditions according to the applicable trip unit characteristics and settings.\u003c\/li\u003e\n\u003cli\u003eShort-Time Protection: Protects against qualifying overcurrent conditions using the trip unit's short-time characteristics.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection: Responds to qualifying high-current fault conditions without an intentional short-time delay.\u003c\/li\u003e\n\u003cli\u003eLSI Trip Configuration: Combines long-time, short-time, and instantaneous functions for electrical systems designed to use this specific protection arrangement.\u003c\/li\u003e\n\u003cli\u003eTA2J6500 Line-Side Lugs: Includes the manufacturer's specified line-side terminal lugs.\u003c\/li\u003e\n\u003cli\u003eTA2J6500 Load-Side Lugs: Includes matching load-side lugs for the stated copper and aluminum conductor ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Low-Voltage Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e SCLD69600NT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217706\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 600 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e LD Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Function Designation:\u003c\/strong\u003e LSI\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Trip Function:\u003c\/strong\u003e Not identified as part of the LSI configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Temperature Designation:\u003c\/strong\u003e Standard 40°C (104°F)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Wire Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Wire Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer-Stated Standards:\u003c\/strong\u003e Meets UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Classification:\u003c\/strong\u003e ECCN EAR99 \/ AL N\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NT molded case circuit breaker includes manufacturer-stated standards and environmental information that can assist with electrical equipment documentation and compliance reviews.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that this breaker meets UL 489 requirements applicable to molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens identifies IEC 60947-2 among the standards met by the SCLD69600NT.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: The manufacturer provides REACH Article 33 duty-to-inform information in relation to the applicable candidate list.\u003c\/li\u003e\n\u003cli\u003eWEEE Information: Siemens identifies no take-back obligation under the WEEE 2012\/19\/EU field in its product data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NT 600A LSI circuit breaker is best suited for existing electrical equipment that requires its current rating, voltage, interrupting capacity, LD-frame construction, and long-time, short-time, and instantaneous trip functions. Potential applications include:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Legacy Siemens Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExisting Commercial Electrical Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Power Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600-Amp Feeder Circuit Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Phase Electrical Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExisting LD-Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensiTrip LSI Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLong-Time, Short-Time, and Instantaneous Protection Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503965053227,"sku":"SCLD69600NT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503965085995,"sku":"SCLD69600NT [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69600nt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}