{"product_id":"scld69600ngt","title":"SCLD69600NGT - 600Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69600NGT - 600Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NGT circuit breaker is a 600-amp, three-pole molded case circuit breaker (MCCB) from the Siemens SENTRON low-voltage product line. Designed for your electrical distribution systems requiring an LD-frame breaker, this model features a 600V AC voltage rating, current-limiting breaking-capacity construction, and a SensiTrip LSIG electronic trip unit. With an interrupting rating of 100kAIC at 600V AC and 150kAIC at 480V AC, it provides clear electrical characteristics to evaluate compatibility with existing commercial and industrial equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600-Amp Current Rating: Provides a defined 600A breaker rating for electrical distribution applications requiring this current capacity.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for compatible three-phase electrical systems that require a three-pole molded-case circuit breaker.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Suitable for consideration in systems operating within the manufacturer's specified voltage rating.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Design: Provides a specific frame configuration for evaluating form and fit in compatible existing electrical equipment.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with the LSIG functions identified for this catalog number.\u003c\/li\u003e\n\u003cli\u003eLong-Time Protection: Addresses sustained overcurrent conditions according to the applicable electronic trip characteristics and settings.\u003c\/li\u003e\n\u003cli\u003eShort-Time Protection: Includes a short-time protection function for qualifying overcurrent conditions, subject to the trip unit's configuration and settings.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection: Provides a trip function for qualifying high-current faults without an intentional short-time delay.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection: Includes the ground-fault function identified by the LSIG designation for systems designed to use this protection element.\u003c\/li\u003e\n\u003cli\u003eIncluded TA2J6500 Line-Side Lugs: Supplied with the manufacturer-specified line-side terminal lugs.\u003c\/li\u003e\n\u003cli\u003eIncluded TA2J6500 Load-Side Lugs: Also includes matching load-side lugs for the stated conductor ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Low-Voltage Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e SCLD69600NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217713\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 600 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e LD Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Function Designation:\u003c\/strong\u003e LSIG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Temperature Designation:\u003c\/strong\u003e Standard 40°C (104°F)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Wire Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Wire Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer-Stated Standards:\u003c\/strong\u003e Meets UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Classification:\u003c\/strong\u003e ECCN EAR99 \/ AL N\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NGT includes manufacturer-provided standards and environmental information to support equipment documentation, maintenance planning, and compatibility reviews.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that the SCLD69600NGT meets UL 489 requirements applicable to molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens also identifies IEC 60947-2 among the standards met by this breaker.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: The manufacturer provides REACH Article 33 duty-to-inform information based on the applicable candidate list.\u003c\/li\u003e\n\u003cli\u003eWEEE Information: Siemens identifies no take-back obligation under the WEEE 2012\/19\/EU field in its product data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600NGT 600A molded case circuit breaker is best suited for existing electrical systems where its electrical ratings, LSIG trip functions, physical dimensions, and terminal connections match approved equipment requirements. Potential applications include:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Commercial Electrical Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600-Amp Feeder Circuit Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Phase Power Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLD-Frame Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensiTrip LSIG Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964954923,"sku":"SCLD69600NGT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964987691,"sku":"SCLD69600NGT [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69600ngt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}