{"product_id":"scld69600","title":"SCLD69600 - 600Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69600 - 600Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600 is a 600-amp, three-pole molded-case circuit breaker from the Siemens SENTRON family, designed for electrical distribution equipment that requires an LD-frame breaker with SensiTrip electronic protection. Rated for 600V AC and featuring a 100kAIC interrupting rating at 600V AC, this breaker provides a specific combination of electrical ratings, physical dimensions, and trip functions for compatible installations. Whether you're maintaining an existing switchboard or finding a replacement for an installed breaker, the SCLD69600 provides clear specifications to help you determine whether it's the right match.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600-Amp Current Rating: Designed for electrical distribution applications requiring a 600A molded case circuit breaker, subject to the equipment's approved configuration and electrical design.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Provides three-pole switching and overcurrent protection for compatible three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Suitable for evaluation in equipment operating at voltages up to the breaker's specified 600V AC rating.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Construction: Part of Siemens' low-voltage SENTRON molded case circuit breaker range, with documented electrical and physical specifications.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Design: Uses the Siemens LD frame, allowing you to compare its dimensions and construction with the requirements of compatible existing equipment.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens SensiTrip electronic overcurrent protection with the LI functions specified for this catalog number.\u003c\/li\u003e\n\u003cli\u003eLong-Time Overcurrent Protection: The long-time trip function protects against sustained overcurrent conditions per the unit's specified characteristics.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Overcurrent Protection: The instantaneous trip function responds to qualifying high-current fault conditions without an intentional short-time delay.\u003c\/li\u003e\n\u003cli\u003eLine-Side Lugs Included: Supplied with TA2J6500 line-side lugs to help identify the required terminal arrangement during compatibility checks.\u003c\/li\u003e\n\u003cli\u003eLoad-Side Lugs Included: Also includes TA2J6500 load-side lugs for the manufacturer-specified conductor sizes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e Siemens SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Low-voltage molded case circuit breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCLD69600\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCLD69600\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Description:\u003c\/strong\u003e SENTRON molded case circuit breaker with electronic trip unit\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 600 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Frame:\u003c\/strong\u003e LD Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Siemens SensiTrip electronic trip unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Functions:\u003c\/strong\u003e LI – Long-Time and Instantaneous\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Delay Protection:\u003c\/strong\u003e Not specified for this LI configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection:\u003c\/strong\u003e Not specified for this LI configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Temperature Reference:\u003c\/strong\u003e 40°C (104°F)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500, included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Wire Range:\u003c\/strong\u003e 3\/0 AWG to 500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Wire Range:\u003c\/strong\u003e 4\/0 AWG to 500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable Standards Identified by Siemens:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217683\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600 includes manufacturer-documented standards and environmental information that may be relevant to equipment maintenance records, replacement evaluations, and project documentation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens identifies the SCLD69600 as meeting UL 489, the standard for molded-case circuit breakers and related protective devices.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens also identifies the breaker as meeting IEC 60947-2, the international standard covering low-voltage circuit breakers.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens provides REACH Article 33 candidate-list substance information for this product.\u003c\/li\u003e\n\u003cli\u003eWEEE Information: Siemens lists no take-back obligation for this product under its WEEE 2012\/19\/EU product data field.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69600 600A circuit breaker is considered for electrical systems where its exact ratings, configuration, and physical characteristics match the equipment's requirements. Potential applications include:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Commercial Electrical Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600-Amp Feeder Circuit Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Phase Power Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLD-Frame Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensiTrip LI Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFacility Electrical Maintenance Programs\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964758315,"sku":"SCLD69600","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964791083,"sku":"SCLD69600 [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69600","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}