{"product_id":"scld69500nt","title":"SCLD69500NT - 500Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69500NT - 500Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500NT circuit breaker is a 500-amp, 3-pole molded case circuit breaker (MCCB) designed for use in your compatible low-voltage electrical distribution equipment. Part of the Siemens SENTRON family, this LD-frame breaker combines a 600V AC voltage rating, a 100kAIC interrupting capacity at 600V AC, and a SensiTrip electronic trip unit with long-time, short-time, and instantaneous (LSI) protection functions. For electrical contractors, facility maintenance teams, and equipment owners working with existing Siemens systems, the SCLD69500NT provides clear specifications to evaluate an exact form, fit, and functional replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500-Amp Current Rating: Designed for electrical distribution circuits requiring a 500A molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Provides three-pole circuit protection for compatible three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Supports evaluation for low-voltage installations operating within the breaker's specified voltage rating.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Construction: Part of Siemens' established low-voltage molded case circuit breaker family.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Design: Identifies the frame configuration needed when checking compatibility with existing electrical equipment.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with the specified LSI protection functions.\u003c\/li\u003e\n\u003cli\u003eLong-Time Overcurrent Protection: Addresses sustained overcurrent conditions according to the electronic trip unit's operating characteristics.\u003c\/li\u003e\n\u003cli\u003eShort-Time Protection: Provides a short-time trip function for qualifying overcurrent conditions, subject to the system's coordination requirements.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Short-Circuit Protection: Includes an instantaneous trip function for high-level short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003eIncluded TA2J6500 Lugs: Features specified line-side and load-side connection lugs for compatible conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e SCLD69500NT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Low-voltage molded case circuit breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e LD frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 500 amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Siemens SensiTrip electronic trip unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Functions:\u003c\/strong\u003e LSI — long-time, short-time, instantaneous\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Trip Function:\u003c\/strong\u003e Not specified for this LSI model\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Breaker Temperature Designation:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReferenced Standards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217669\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens identifies the SCLD69500NT as meeting UL 489 requirements for molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens also specifies that the breaker meets IEC 60947-2, the international standard addressing low-voltage circuit breakers.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens provides a REACH Article 33 information reference concerning substances on the current candidate list. This reference should not be interpreted as an unrestricted declaration covering every REACH obligation.\u003c\/li\u003e\n\u003cli\u003eWEEE Take-Back Obligations: Siemens lists the WEEE (2012\/19\/EU) take-back obligations field as \"5.\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Legacy Siemens Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e500A Electrical Distribution Circuits\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Equipment Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommercial Power Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLSI Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExisting LD-Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Connections\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Connections\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFacility Electrical Maintenance Programs\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964594475,"sku":"SCLD69500NT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964627243,"sku":"SCLD69500NT [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69500nt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}