{"product_id":"scld69500ngt","title":"SCLD69500NGT - 500Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69500NGT - 500Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500NGT circuit breaker is a 500-amp, three-pole SENTRON molded case circuit breaker (MCCB) for your electrical distribution equipment that requires a specific combination of current rating, frame dimensions, and electronic trip functions. Rated for 600V AC, this Siemens LD-frame breaker features 100kAIC interrupting capacity at 600V AC and 150kAIC at 480V AC. Its current-limiting breaking-capacity construction and standard 40°C breaker designation are part of the manufacturer's specifications, making them important details when evaluating the breaker for compatible commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500-Amp Current Rating: Provides a manufacturer-defined 500A rating for compatible electrical distribution applications requiring this breaker capacity.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for three-pole electrical systems and equipment approved for this breaker arrangement.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Supports applications within the specified voltage rating when all other equipment and system requirements are satisfied.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Product Design: Identifies the breaker as part of the Siemens SENTRON molded case circuit breaker line.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Construction: Provides a defined frame configuration for evaluating physical compatibility with existing equipment.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip functions identified by the LSIG designation.\u003c\/li\u003e\n\u003cli\u003eLong-Time Protection: Addresses sustained overcurrent conditions according to the applicable trip characteristics and settings.\u003c\/li\u003e\n\u003cli\u003eShort-Time Protection: Includes a short-time trip function for qualifying overcurrent conditions, subject to the unit's available settings and application requirements.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection: Provides a trip response for qualifying high-current fault conditions without intentional delay.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection: Includes the ground-fault trip function specified by Siemens for this LSIG configuration.\u003c\/li\u003e\n\u003cli\u003eIncluded TA2J6500 Line and Load Lugs: Provide manufacturer-identified terminals on both sides of the breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e SCLD69500NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217676\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 500 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e LD Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Trip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Function Designation:\u003c\/strong\u003e LSIG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection (L):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection (S):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection (I):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection (G):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Breaker Temperature Designation:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer-Stated Standards:\u003c\/strong\u003e Meets UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Classification:\u003c\/strong\u003e ECCN EAR99 \/ AL N\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Catalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500NGT includes manufacturer-stated standards and environmental information that can help electrical professionals review documentation requirements for an existing installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that the SCLD69500NGT meets UL 489 requirements for molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens also identifies IEC 60947-2 as a standard this model meets.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with the applicable substance restrictions under the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens references REACH Article 33 duty-to-inform information based on the current candidate list.\u003c\/li\u003e\n\u003cli\u003eWEEE (2012\/19\/EU) Take-Back Obligations: Siemens identifies this field as No.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible Legacy Siemens Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e500A Electrical Distribution Circuits\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Equipment Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommercial Power Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLSIG Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExisting LD-Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964496171,"sku":"SCLD69500NGT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964528939,"sku":"SCLD69500NGT [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69500ngt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}