{"product_id":"scld69500g","title":"SCLD69500G - 500Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69500G - 500Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500G circuit breaker is a 500-amp, three-pole molded case circuit breaker (MCCB) from the Siemens SENTRON family. Designed for your electrical distribution equipment that requires an LD-frame breaker, this model combines a 600V AC voltage rating, current-limiting breaking capacity, and a SensiTrip electronic trip unit. With an interrupting rating of 100kAIC at 600V AC and 150kAIC at 480V AC, it provides clearly defined specifications for evaluating compatibility with commercial and industrial electrical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500-Amp Current Rating: Provides a defined 500A breaker rating for electrical distribution applications that require this capacity.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for compatible three-pole electrical distribution arrangements.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Suitable for consideration in systems operating within the breaker's specified voltage rating.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Construction: Part of the Siemens SENTRON molded case circuit breaker product line.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Design: Supports form and fit evaluations for equipment specifically approved to accept this frame and breaker configuration.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates electronic trip functions identified by Siemens for this model.\u003c\/li\u003e\n\u003cli\u003eLong-Time Protection: Addresses sustained overcurrent conditions according to the applicable trip settings and characteristics.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection: Provides an instantaneous trip function for qualifying high-current fault conditions.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection Function: Includes the ground-fault element identified by the LIG designation, subject to appropriate system application and configuration.\u003c\/li\u003e\n\u003cli\u003eIncluded TA2J6500 lugs include the line-side and load-side lugs for this breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e SCLD69500G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217652\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 500 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e LD Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Function Designation:\u003c\/strong\u003e LIG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection:\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection:\u003c\/strong\u003e Not specified as part of the LIG configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Temperature Designation:\u003c\/strong\u003e Standard 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Construction:\u003c\/strong\u003e Current-limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Wire Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Wire Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.5 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W × H × D):\u003c\/strong\u003e 7.5 × 17.86 × 4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer-Stated Standards:\u003c\/strong\u003e Meets UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Classification:\u003c\/strong\u003e ECCN EAR99 \/ AL N\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500G includes manufacturer-provided standards and environmental compliance information to support product identification and documentation reviews.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that this molded case circuit breaker meets UL 489 requirements.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens also identifies IEC 60947-2 among the standards met by this product.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens lists compliance with the applicable substance restrictions according to the RoHS directive since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: The manufacturer provides a reference to REACH Article 33 duty-to-inform information based on the applicable candidate list. This reference should not be interpreted as a blanket statement of REACH compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69500G is intended for consideration in electrical systems where its exact ratings, configuration, and physical characteristics match the equipment's requirements. Potential applications include:\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Commercial Electrical Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Switchboards\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Equipment Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Phase Power Distribution\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLD-Frame Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLIG Electronic Trip Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCopper-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAluminum-Conductor Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964397867,"sku":"SCLD69500G","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964430635,"sku":"SCLD69500G [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69500g","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}