{"product_id":"scld69400g","title":"SCLD69400G - 400Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCLD69400G - 400Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69400G circuit breaker is a 400-amp, 3-pole molded-case circuit breaker (MCCB) for your compatible commercial and industrial electrical distribution systems. Part of the Siemens SENTRON family, this LD-frame circuit breaker combines a 600V AC voltage rating, current-limiting breaking-capacity construction, and a SensiTrip electronic trip unit with LIG protection functions. For electricians, maintenance teams, and facility managers working with established electrical equipment, the SCLD69400G offers a specific combination of electrical ratings, trip functions, and physical dimensions for form, fit, and functional replacement evaluation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400-Amp Current Rating: Designed for electrical applications requiring a 400A molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Intended for compatible three-phase electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003e600V AC Voltage Rating: Supports applications within the breaker's specified voltage rating.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Construction: Part of Siemens' low-voltage molded case circuit breaker family.\u003c\/li\u003e\n\u003cli\u003eLD-Frame Design: Identifies the physical breaker frame for approved mounting and equipment compatibility.\u003c\/li\u003e\n\u003cli\u003eElectronic SensiTrip Trip Unit: Incorporates Siemens electronic trip technology with LIG protection functions.\u003c\/li\u003e\n\u003cli\u003eLong-Time Overcurrent Protection: Addresses sustained overcurrent conditions according to the trip unit's operating characteristics.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Short-Circuit Protection: Responds to high-level short-circuit conditions through its instantaneous trip function.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection: Adds a dedicated ground-fault trip function to the specified protection configuration.\u003c\/li\u003e\n\u003cli\u003eIncluded Line and Load Lugs: Equipped with TA2J6500 lugs for compatible conductor connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCLD69400G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCLD69400G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Frame:\u003c\/strong\u003e LD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 400 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Technology:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Configuration:\u003c\/strong\u003e LIG (Long-Time, Instantaneous, Ground-Fault)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection:\u003c\/strong\u003e Yes\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Trip Function:\u003c\/strong\u003e Not included in the specified LIG configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Design:\u003c\/strong\u003e Current Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Breaker Temperature Reference:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lug Type:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lug Type:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.50 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217614\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCLD69400G circuit breaker includes manufacturer-published standards and environmental compliance information for electrical installation planning, maintenance records, and equipment documentation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens identifies the SCLD69400G as meeting UL 489 requirements for molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: The manufacturer states that the breaker meets IEC 60947-2 requirements for low-voltage circuit breakers.\u003c\/li\u003e\n\u003cli\u003eRoHS Directive: Siemens reports compliance with applicable substance restrictions since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens provides information concerning its duty to communicate substances appearing on the applicable REACH candidate list. Review specific substance declarations in the current manufacturer documentation.\u003c\/li\u003e\n\u003cli\u003eWEEE Directive (2012\/19\/EU): Siemens lists a value of 5 in its WEEE take-back obligations field. The supplied information does not define this value.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy Siemens LD-Frame Breaker Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Commercial Power Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThree-Phase Feeder Circuits\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e400-Amp Electrical Distribution Applications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible 480V AC Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible 600V AC Electrical Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInstallations Requiring LIG Electronic Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApproved Switchboard Assemblies\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndustrial Facility Electrical Maintenance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCommercial Building Electrical System Repairs\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503964004651,"sku":"SCLD69400G","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503964037419,"sku":"SCLD69400G [R]","price":5000.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scld69400g","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}