{"product_id":"scjd69400ngt","title":"SCJD69400NGT - 400Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCJD69400NGT - 400Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCJD69400NGT circuit breaker is a 400-amp, 3-pole molded case circuit breaker (MCCB) designed for your compatible commercial and industrial electrical distribution systems. Part of the Siemens SENTRON family, this breaker features an SJD configuration, JD frame, and SensiTrip electronic trip unit (ETU) with long-time, short-time, instantaneous, and ground-fault (LSIG) protection functions. Rated for applications up to 600V AC, the SCJD69400NGT provides an interrupting capacity of 100kA at 600V AC and 150kA at 480V AC, making these ratings important considerations when matching a replacement breaker to an existing installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400-Amp Current Rating: Designed for electrical distribution applications requiring a 400A molded case circuit breaker with the specified frame and electronic trip configuration.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Circuit Protection: Provides overcurrent protection across three poles in compatible three-phase electrical systems.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Construction: Part of Siemens' SENTRON molded case circuit breaker family, with defined electrical ratings, physical dimensions, and conductor connections.\u003c\/li\u003e\n\u003cli\u003eSJD Configuration and JD Frame: Uses the manufacturer-specified breaker designation and frame arrangement for applications requiring this exact configuration.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with four protection functions identified by the LSIG designation.\u003c\/li\u003e\n\u003cli\u003eLong-Time Protection (L): Addresses sustained overload conditions according to the electronic trip unit's applicable characteristics and settings.\u003c\/li\u003e\n\u003cli\u003eShort-Time Protection (S): Provides a short-time trip function for applicable overcurrent conditions, subject to the unit's settings and system coordination requirements.\u003c\/li\u003e\n\u003cli\u003eInstantaneous Protection (I): Provides a trip function for high-level overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection (G): Includes a ground-fault trip function for applications requiring this protection feature, subject to proper installation and configuration.\u003c\/li\u003e\n\u003cli\u003eTA2J6500 Line and Load Lugs: Includes the manufacturer's specified lug arrangement on both sides of the breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCJD69400NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCJD69400NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Designation:\u003c\/strong\u003e SJD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e JD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 400 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kA (100,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kA (150,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Trip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Configuration:\u003c\/strong\u003e LSIG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection (L):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection (S):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection (I):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection (G):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Design:\u003c\/strong\u003e Current-Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Temperature Rating:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lug Type:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lug Type:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.50 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable Standards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Substance Restrictions Compliance:\u003c\/strong\u003e Reported since March 30, 2009\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Article 33:\u003c\/strong\u003e Manufacturer references applicable duty-to-inform requirements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSCIP Number:\u003c\/strong\u003e Not available\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE (2012\/19\/EU) Take-Back Obligations:\u003c\/strong\u003e No, according to the supplied Siemens specifications\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217232\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Catalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer-reported material and standards information includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that the SCJD69400NGT meets the applicable molded case circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens identifies compliance with the applicable international circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with applicable substance restrictions since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens provides a reference to its duty-to-inform information concerning substances on the applicable candidate list.\u003c\/li\u003e\n\u003cli\u003eWEEE Directive (2012\/19\/EU): Siemens reports no take-back obligation for this product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Siemens SCJD69400NGT Circuit Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Siemens SENTRON Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens SJD \/ JD Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e400-Amp Three-Pole Circuit Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Systems Requiring 100kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Systems Requiring 150kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Systems Requiring LSIG Electronic Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Long-Time Overload Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Short-Time Overcurrent Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Instantaneous Overcurrent Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Ground-Fault Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Commercial and Industrial Electrical Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503963316523,"sku":"SCJD69400NGT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503963349291,"sku":"SCJD69400NGT [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scjd69400ngt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}