{"product_id":"scjd69400g","title":"SCJD69400G - 400Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCJD69400G - 400Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCJD69400G is a 400-amp, 3-pole molded-case circuit breaker (MCCB) for your compatible commercial and industrial electrical distribution systems. Part of the Siemens SENTRON family, this breaker features an SJD configuration, JD frame, and SensiTrip electronic trip unit (ETU) with long-time, instantaneous, and ground-fault (LIG) protection functions. Rated for electrical systems up to 600V AC, the SCJD69400G has an interrupting capacity of 100kA at 600V AC and 150kA at 480V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400-Amp Current Rating: Designed for electrical distribution applications requiring a 400A molded case circuit breaker with the specified Siemens frame and trip configuration.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Circuit Protection: Provides overcurrent protection across three poles in compatible three-phase electrical distribution systems.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON Design: Part of the SENTRON molded case circuit breaker family, with manufacturer-defined ratings, connections, and dimensions.\u003c\/li\u003e\n\u003cli\u003eSJD Configuration and JD Frame: Uses the specified Siemens breaker designation and frame type for applications requiring this physical configuration.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with long-time, instantaneous, and ground-fault protection functions.\u003c\/li\u003e\n\u003cli\u003eLIG Protection Configuration: Includes long-time (L), instantaneous (I), and ground-fault (G) protection for systems requiring this exact trip arrangement.\u003c\/li\u003e\n\u003cli\u003eGround-Fault Protection Function: Provides ground-fault tripping as part of the LIG configuration, subject to proper settings, installation, and system requirements.\u003c\/li\u003e\n\u003cli\u003eTA2J6500 Line and Load Lugs: Includes the manufacturer's specified lug arrangement on both sides of the breaker.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCJD69400G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCJD69400G\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Designation:\u003c\/strong\u003e SJD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e JD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 400 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kA (100,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kA (150,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Configuration:\u003c\/strong\u003e LIG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection (L):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection (I):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Protection (G):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection (S):\u003c\/strong\u003e Not part of the specified LIG configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Design:\u003c\/strong\u003e Current-Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Temperature Rating:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.50 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable Standards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Substance Restrictions Compliance:\u003c\/strong\u003e Reported since March 30, 2009\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217218\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Catalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer-reported compliance and material information includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that the SCJD69400G meets the applicable molded case circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Siemens identifies compliance with the applicable international circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with applicable substance restrictions since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens references the applicable duty-to-inform requirements. Confirm current substance information through manufacturer documentation.\u003c\/li\u003e\n\u003cli\u003eWEEE Directive (2012\/19\/EU): Siemens identifies a take-back obligation classification of 5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Siemens SCJD69400G Circuit Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Siemens SENTRON Electrical Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens SJD \/ JD Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e400-Amp Three-Pole Circuit Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Systems Requiring 100kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Systems Requiring 150kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Systems Requiring LIG Electronic Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Long-Time Overload Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Instantaneous Overcurrent Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Ground-Fault Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Commercial and Industrial Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503963119915,"sku":"SCJD69400G","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503963152683,"sku":"SCJD69400G [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scjd69400g","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}