{"product_id":"scjd69300nt","title":"SCJD69300NT - 300Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCJD69300NT - 300Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCJD69300NT is a 300-amp, 3-pole molded-case circuit breaker (MCCB) for your compatible commercial and industrial electrical distribution systems. As part of the Siemens SENTRON family, this breaker features an SJD configuration, a JD frame, and a Siemens SensiTrip electronic trip unit (ETU) with LSI protection functions. Rated for applications up to 600V AC, the SCJD69300NT has an interrupting capacity of 100kA at 600V AC and 150kA at 480V AC, providing the specific electrical ratings needed for certain existing Siemens installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e300-Amp Current Rating: Designed for electrical distribution systems requiring a 300A molded case circuit breaker with the specified Siemens frame and trip configuration.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Design: Provides three-pole circuit protection for compatible electrical equipment and three-phase distribution applications.\u003c\/li\u003e\n\u003cli\u003eSiemens SENTRON SJD\/JD Frame: Features the manufacturer-specified SJD breaker configuration and JD frame, helping maintenance professionals identify the correct physical and functional replacement.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology with LSI protection functions for applications requiring this particular overcurrent protection arrangement.\u003c\/li\u003e\n\u003cli\u003eLSI Protection Functions: Includes long-time, short-time, and instantaneous protection to address different overcurrent conditions within an appropriately designed electrical system.\u003c\/li\u003e\n\u003cli\u003eLine and Load Side Lugs Included: Equipped with TA2J6500 lugs on both sides of the breaker for the specified conductor ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCJD69300NT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCJD69300NT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Designation:\u003c\/strong\u003e SJD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e JD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 300 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kA (100,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kA (150,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Configuration:\u003c\/strong\u003e LSI\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Time Protection (L):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Time Protection (S):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstantaneous Protection (I):\u003c\/strong\u003e Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround-Fault Trip Protection (G):\u003c\/strong\u003e Not part of the specified LSI configuration\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Design:\u003c\/strong\u003e Current-Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Temperature Rating:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.50 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable Standards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Substance Restrictions Compliance:\u003c\/strong\u003e Reported since March 30, 2009\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217188\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Catalog ID:\u003c\/strong\u003e LV10.1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Product Group:\u003c\/strong\u003e 3741\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSiemens Group Code:\u003c\/strong\u003e P360\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 8536200020\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer-reported compliance information includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens identifies the SCJD69300NT as meeting the applicable molded case circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Manufacturer-reported compliance with the applicable international circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with applicable substance restrictions since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens references the applicable duty-to-inform requirements. Confirm current substance information through manufacturer documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Siemens SCJD69300NT Circuit Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Siemens SENTRON Electrical Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens SJD \/ JD Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e300-Amp Three-Pole Circuit Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Systems Requiring 100kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Systems Requiring 150kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Systems Requiring LSI Electronic Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eApplications Requiring Long-Time and Short-Time Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Systems Requiring Instantaneous Overcurrent Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Commercial Electrical Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Industrial Switchboards and Distribution Assemblies\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503962923307,"sku":"SCJD69300NT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503962956075,"sku":"SCJD69300NT [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scjd69300nt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}