{"product_id":"scjd69200ngt","title":"SCJD69200NGT - 200Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eSCJD69200NGT - 200Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens SCJD69200NGT circuit breaker is a 200-amp, 3-pole molded-case breaker for your compatible commercial and industrial electrical distribution systems. As part of the Siemens SENTRON line, this SJD breaker features a JD-frame design, a SensiTrip electronic trip unit (ETU), and LSIG protection for long-time, short-time, instantaneous, and ground-fault protection. With a maximum voltage rating of 600V AC and an interrupting capacity of 100kA at 600V AC, the SCJD69200NGT suits installations that require these electrical ratings and protection characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200-Amp Current Rating: Provides circuit protection for compatible electrical distribution equipment designed to accommodate a 200A molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003eThree-Pole Configuration: Designed for three-pole electrical applications requiring coordinated interruption of the protected conductors.\u003c\/li\u003e\n\u003cli\u003eSiemens SJD \/ JD Frame Construction: Uses a defined frame design to support proper matching with approved Siemens electrical equipment and existing installations.\u003c\/li\u003e\n\u003cli\u003eSensiTrip Electronic Trip Unit: Incorporates Siemens electronic trip technology for the specified overcurrent and ground-fault protection functions.\u003c\/li\u003e\n\u003cli\u003eLSIG Protection Functions: Provides long-time, short-time, instantaneous, and ground-fault protection, allowing the breaker to serve applications requiring this particular trip-function combination.\u003c\/li\u003e\n\u003cli\u003eIncluded Line and Load Side Lugs: Equipped with TA2J6500 lugs to accommodate the specified copper and aluminum conductor sizes.\u003c\/li\u003e\n\u003cli\u003eStandard 40°C Temperature Rating: Provides a defined operating temperature reference for evaluating the breaker within compatible electrical equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e SCJD69200NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MFN):\u003c\/strong\u003e SCJD69200NGT\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Article Number:\u003c\/strong\u003e US2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker (MCCB)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Designation:\u003c\/strong\u003e SJD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e JD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 200 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 600V AC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 600V AC:\u003c\/strong\u003e 100kA (100,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity at 480V AC:\u003c\/strong\u003e 150kA (150,000 Amps)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit Type:\u003c\/strong\u003e Electronic Trip Unit (ETU)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip System:\u003c\/strong\u003e Siemens SensiTrip\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Functions:\u003c\/strong\u003e LSIG – Long-Time, Short-Time, Instantaneous, and Ground-Fault\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking-Capacity Design:\u003c\/strong\u003e Current-Limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Temperature Rating:\u003c\/strong\u003e 40°C\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad-Side Lugs:\u003c\/strong\u003e TA2J6500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper Conductor Range:\u003c\/strong\u003e 3\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAluminum Conductor Range:\u003c\/strong\u003e 4\/0 AWG–500 kcmil\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 7.50 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 17.86 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.00 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 34.00 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplicable Standards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643217157\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eManufacturer-reported compliance information includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL 489: Siemens states that the SCJD69200NGT meets this standard for molded case circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIEC 60947-2: Manufacturer-reported compliance with this international circuit breaker standard.\u003c\/li\u003e\n\u003cli\u003eRoHS Substance Restrictions: Siemens reports compliance with applicable substance restrictions since March 30, 2009.\u003c\/li\u003e\n\u003cli\u003eREACH Article 33: Siemens references the applicable duty-to-inform requirements; consult current manufacturer documentation for any specific substance declarations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExisting Siemens SCJD69200NGT Circuit Breaker Replacements\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Siemens SENTRON Electrical Distribution Systems\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLegacy Siemens SJD \/ JD Frame Installations\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e200-Amp Three-Pole Circuit Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e600V AC Systems Requiring 100kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e480V AC Systems Requiring 150kA Interrupting Capacity\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElectrical Systems Requiring LSIG Electronic Trip Protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Commercial Electrical Distribution Equipment\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Industrial Switchboards and Distribution Assemblies\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49503962431787,"sku":"SCJD69200NGT","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49503962464555,"sku":"SCJD69200NGT [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/scjd69200ngt","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}