{"product_id":"kts-r-2","title":"KTS-R-2 - 2Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eKTS-R-2 - 2Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeed a KTS-R-2? Here are the details worth checking before you make the match. This Eaton Bussmann series fuse is rated 2A at 600V and carries a Class RK1 classification. The manufacturer lists an interrupt rating of 200 kAIC at 600 Vac, along with a ferrule design and single-element construction. The fuse is also listed as non-indicating and CE-marked. In short, you have the important numbers in one place—making it easier to check the KTS-R-2 against the fuse you're replacing instead of relying on amperage alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2A, 600V rating for straightforward specification matching.\u003c\/li\u003e\n\u003cli\u003eClass RK1 fuse classification helps narrow the replacement search quickly.\u003c\/li\u003e\n\u003cli\u003eFerrule design is listed as a special feature for the KTS-R-2.\u003c\/li\u003e\n\u003cli\u003eSingle-element construction according to the manufacturer's specifications.\u003c\/li\u003e\n\u003cli\u003eListed as a non-indicating fuse.\u003c\/li\u003e\n\u003cli\u003eCE Marked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Name:\u003c\/strong\u003e Eaton Bussmann series KTS-R fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e KTS-R-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 051712417310\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 2 A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 200 kAIC at 600 Vac\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass:\u003c\/strong\u003e Class RK1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Elements:\u003c\/strong\u003e 1\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Ferrule design\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Length\/Depth:\u003c\/strong\u003e 5 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Height:\u003c\/strong\u003e 0.81 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Width:\u003c\/strong\u003e 0.81 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e 0.15 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliances:\u003c\/strong\u003e CE Marked\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe KTS-R-2 is CE Marked, according to the supplied manufacturer specifications. No construction material or other compliance designation was supplied for this specific catalog number, so don't assume those details from other KTS-R models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton Bussmann KTS-R-2 is worth checking when the equipment documentation specifies a 2A, 600V Class RK1 fuse and the other listed characteristics match the application. In particular, compare the 200 kAIC at 600 Vac interrupt rating, ferrule design, and physical dimensions with the equipment requirements.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOne quick rule for replacement work: don't stop at \"2 amp.\" Check the catalog number, fuse class, voltage, interrupt rating, dimensions, and the equipment manufacturer's requirements. A few extra seconds spent comparing those details can prevent a poor match.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Edison®, Edison Fuse®, GTE Sylvania®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"New In Box","offer_id":50459245478187,"sku":"KTS-R-2","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459245510955,"sku":"KTS-R-2  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/kts-r-2","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}