{"product_id":"hrxd63b160","title":"HRXD63B160 - 1600 Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eHRXD63B160 - 1600 Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen you're matching a breaker for an existing RD-frame installation, the catalog number is only the beginning. The Siemens HRXD63B160 is a 1600A, 3-pole SENTRON molded case circuit breaker rated for 600V, with a thermal-magnetic, non-interchangeable trip unit. Siemens specifies that the HRXD63B160 meets UL 489 and IEC 60947-2 standards and identifies it as a standard 40°C RD-frame breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1600A current rating: Provides a clear match point for equipment requiring a 1600-amp breaker with the remaining HRXD63B160 specifications.\u003c\/li\u003e\n\u003cli\u003e3-pole configuration: Designed with three poles, an essential detail when matching an existing breaker arrangement.\u003c\/li\u003e\n\u003cli\u003e600V rating: Matches electrical equipment requiring this voltage rating and a compatible breaker type.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit: Uses the trip technology specified by Siemens for this SENTRON molded case circuit breaker.\u003c\/li\u003e\n\u003cli\u003eNon-interchangeable trip: The trip unit is specifically identified as non-interchangeable, an important point when evaluating replacement compatibility.\u003c\/li\u003e\n\u003cli\u003eRD-frame construction: Gives technicians another specific identifier to compare against the existing breaker and equipment documentation.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number \/ MFN:\u003c\/strong\u003e HRXD63B160\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e US2:HRXD63B160\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e SENTRON\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e HRD6, 50 kAIC, 600 VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e RD\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating:\u003c\/strong\u003e 1600 A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating at 600 V:\u003c\/strong\u003e 50 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating at 480 V:\u003c\/strong\u003e 65 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Unit:\u003c\/strong\u003e Thermal-Magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Configuration:\u003c\/strong\u003e Non-Interchangeable\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Designation:\u003c\/strong\u003e Standard 40°C breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLugs:\u003c\/strong\u003e No lugs installed\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 9 in.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 16 in.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 6.19 in.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 9 x 16 x 6.19 in.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 46.8 lb.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643247758\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommodity Code:\u003c\/strong\u003e 85362099\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExport Classification:\u003c\/strong\u003e EAR99\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDangerous Goods Classification:\u003c\/strong\u003e No\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSiemens states that the HRXD63B160 meets UL 489 and IEC 60947-2 standards. That wording is kept intentionally precise; the supplied manufacturer information does not provide a separate UL listing or certification statement, other than stating that the breaker meets these standards.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe Siemens HRXD63B160 makes sense for maintaining compatible existing or legacy equipment that specifically calls for a 1600A, 3-pole RD-frame molded-case circuit breaker with a thermal-magnetic, non-interchangeable trip unit. Its 600V rating, interrupt ratings, frame, physical dimensions, and no-lugs configuration provide meaningful details for comparison with the breaker being replaced.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49504190038315,"sku":"HRXD63B160","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49504190071083,"sku":"HRXD63B160 [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/hrxd63b160","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}