{"product_id":"hnd63b900l","title":"HND63B900L - 900Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eHND63B900L - 900Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HND63B900L Siemens Sentron molded-case circuit breaker is a 900-amp, three-pole breaker designed for your electrical distribution systems where matching the existing breaker configuration, ratings, and connection requirements is essential. This ND frame circuit breaker uses a thermal-magnetic trip unit. It is commonly used in commercial and industrial applications where reliable overload and short-circuit protection is required while maintaining the original equipment setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e900 Amp three-pole molded case circuit breaker\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit for overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eND frame design for compatible replacement applications\u003c\/li\u003e\n\u003cli\u003eRated for 600VAC systems\u003c\/li\u003e\n\u003cli\u003eIncludes line-side and load-side lugs\u003c\/li\u003e\n\u003cli\u003eTA4N8500 lug configuration\u003c\/li\u003e\n\u003cli\u003eAccepts 250–500 kcmil copper or aluminum conductors\u003c\/li\u003e\n\u003cli\u003eMeets UL 489 and IEC 60947-2 standards\u003c\/li\u003e\n\u003cli\u003eDesigned for commercial and industrial electrical distribution systems\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e HND63B900L\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Siemens\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Molded Case Circuit Breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e ND\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 900 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e50kAIC at 600VAC\u003c\/li\u003e\n\u003cli\u003e65kAIC at 480VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL 489 \/ IEC 60947-2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLugs:\u003c\/strong\u003e Line and Load Side Lugs Included\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Type:\u003c\/strong\u003e TA4N8500\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Range:\u003c\/strong\u003e 250–500 kcmil CU\/AL\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9\"W x 16\"H x 6\"D\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Dimensions:\u003c\/strong\u003e 18.898\" x 11.811\" x 9.843\"\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e 61.619 lbs\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 783643008854\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e HND6, 50kAIC, 600VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HND63B900L Siemens Sentron molded-case circuit breaker is manufactured to meet the UL 489 and IEC 60947-2 standards. It is intended for use in compatible electrical distribution equipment in which the breaker frame, voltage rating, interrupting capacity, lug configuration, and installation requirements match those of the existing system.\u003c\/p\u003e\n\u003cp\u003eInstallation should be performed by qualified electrical personnel and completed in accordance with applicable electrical codes, safety practices, and manufacturer guidelines.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSiemens Sentron electrical distribution equipment\u003c\/li\u003e\n\u003cli\u003eIndustrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eCommercial electrical installations\u003c\/li\u003e\n\u003cli\u003eExisting ND frame breaker applications\u003c\/li\u003e\n\u003cli\u003eFeeder and main circuit protection applications\u003c\/li\u003e\n\u003cli\u003eSystems requiring a 900 Amp three-pole breaker\u003c\/li\u003e\n\u003cli\u003eApplications requiring thermal magnetic overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eEquipment requiring factory-installed line and load lugs\u003c\/li\u003e\n\u003cli\u003eMaintenance and replacement projects where matching existing breaker specifications is important\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":49504187220267,"sku":"HND63B900L","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49504187253035,"sku":"HND63B900L [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/hnd63b900l","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}