{"product_id":"hkd3400f","title":"HKD3400F - 400Amp Max. *Frame Only*","description":"\u003cp\u003e\u003cstrong\u003eHKD3400F - 400Amp Max. *Frame Only*\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eaton HKD3400F is a durable frame-only unit from the Series C family, rated for 400 amps and operating at 600 Vac and 250 Vdc. Ideal for industrial and commercial use, this three-pole unit features fixed thermal and magnetic trip protection with a 100 kAIC interrupt rating at 240 Vac and 65 kAIC at 480 Vac. As a frame-only unit, it requires a separate trip unit to function as a complete circuit breaker, allowing customizable protection based on specific system needs. This is a frame-only model and requires a compatible trip unit to function as a complete circuit breaker.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eImportant Note:\u003c\/b\u003e This item requires the installation of a compatible trip unit to function as a complete circuit breaker. Available trip unit sizes include:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0in;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e100A (KT3100T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e125A (KT3125T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e150A (KT3150T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e175A (KT3175T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e200A (KT3200T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e225A (KT3225T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e250A (KT3250T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e300A (KT3300T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e350A (KT3350T)\u003c\/b\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\u003cb\u003e400A (KT3400T)\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003ePlease ensure the appropriate trip unit is selected based on your specific application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Only Design:\u003c\/strong\u003e Requires a trip unit for full functionality, allowing for customizable protection configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Interrupting Capacity:\u003c\/strong\u003e Rated 100 kAIC at 240 Vac and 65 kAIC at 480 Vac for enhanced safety in fault conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Thermal and Magnetic Trip:\u003c\/strong\u003e Delivers reliable and consistent overload and short circuit protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 400A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 Vac, 250 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Fixed thermal, fixed magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Rating:\u003c\/strong\u003e 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating: \u003c\/strong\u003e100 kAIC at 240 Vac, 65 kAIC at 480 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles: \u003c\/strong\u003e3\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis product is UL Listed, meeting industry standards for safety and performance. Backed by Eaton's Selling Policy 25-000, the HKD3400F is covered by a one-year warranty from the date of installation or 18 months from the date of shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSuitability:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for use in industrial and commercial environments where custom circuit protection is required. This frame is suited for applications needing 400A capacity and high interrupting performance in challenging electrical conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy choosing the Eaton HKD3400F, you get a flexible, high-quality foundation for building a customized circuit protection system.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"EATON","offers":[{"title":"New In Box","offer_id":49499239645483,"sku":"HKD3400F","price":3062.86,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":49499239678251,"sku":"HKD3400F [R]","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/0758\/1995\/files\/HKD3400F.png?v=1741623872","url":"https:\/\/store.circuitbreakersuperstore.com\/products\/hkd3400f","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}