{"product_id":"hgb3b060b","title":"HGB3B060B - 60Amp Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eHGB3B060B - 60Amp Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen you’re replacing a circuit breaker, the details matter. The HGB3B060B is a 60-amp, 3-pole HGB G-frame circuit breaker made for compatible low-voltage panelboard applications. It uses a thermal-magnetic trip unit to provide overload and short-circuit protection and carries interrupting ratings of 14 kAIC at 600Y\/347V and 35 kAIC at 480Y\/277V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e60-amp, 3-pole design for applications requiring this specific HGB configuration.\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip unit provides both overload and short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eTC1GG20 load-side lugs make the connection configuration easy to identify.\u003c\/li\u003e\n\u003cli\u003eHandles 8 AWG to 1\/0 AWG copper or aluminum conductors, giving installers flexibility with compatible wiring.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e HGB3B060B\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker Type:\u003c\/strong\u003e Low-voltage panelboard circuit breaker\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e HGB G-Frame\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmp Rating:\u003c\/strong\u003e 60A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal-magnetic\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 600Y\/347V:\u003c\/strong\u003e 14 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 480Y\/277V:\u003c\/strong\u003e 35 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Configuration:\u003c\/strong\u003e Load-side lugs only\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLug Type:\u003c\/strong\u003e TC1GG20\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Range:\u003c\/strong\u003e 8 AWG–1\/0 AWG\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Compatibility:\u003c\/strong\u003e Copper or aluminum (Cu\/Al)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 3 x 5.4 x 2.8 in.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 2.756 lb.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 887621219840\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Mexico\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HGB3B060B is UL Listed. Available product data also identifies its export-control classification as ECCN EAR99 \/ AL N and lists the breaker as not dangerous goods.\u003c\/p\u003e\n\u003cp\u003eEnvironmental documentation includes WEEE and REACH information. RoHS compliance information is listed as unavailable, and a SCIP number is not provided. Rather than filling in missing compliance details with assumptions, these items should be confirmed when they are important to a particular project or specification.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe HGB3B060B makes the most sense in compatible low-voltage panelboard applications that call for a 60A, three-pole HGB G-frame breaker with the specified interrupting ratings. It can be a particularly useful match when maintaining an existing commercial or industrial electrical system where the original breaker catalog number and physical configuration need to be closely duplicated.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSiemens®, I-T-E®, and Murray® are registered trademarks of Siemens AG. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Siemens AG or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SIEMENS","offers":[{"title":"New In Box","offer_id":50454377857323,"sku":"HGB3B060B","price":448.57,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/hgb3b060b","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}