{"product_id":"h363dx","title":"H363DX - 100A Safety Switch","description":"\u003cp\u003e\u003cstrong\u003eH363DX - 100A Safety Switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplacing a safety switch isn't always as simple as matching the label amperage. You also need the right pole configuration, electrical ratings, enclosure characteristics, and physical dimensions. Get one detail wrong, and a replacement that looks suitable on paper may not fit the existing installation.\u003c\/p\u003e\n\u003cp\u003eThe H363DX 100 Amp Safety Switch has a three-pole configuration and a 100-amp current rating. These specifications provide a starting point when comparing it with an existing safety switch. The supplied product data also lists 600 under the combined field \"A.I.C. Rating \u0026amp; Volts.\" We are provisionally treating that value as a 600V rating. Still, you should confirm the actual voltage and applicable short-circuit current ratings in the manufacturer documentation or on the equipment nameplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100-Amp Current Rating\u003c\/li\u003e\n\u003cli\u003e3-Pole Configuration\u003c\/li\u003e\n\u003cli\u003eProvisionally Listed 600-Volt Rating\u003c\/li\u003e\n\u003cli\u003eElectrical Disconnect Function\u003c\/li\u003e\n\u003cli\u003eForm, Fit, and Functional Replacement\u003c\/li\u003e\n\u003cli\u003eExisting Electrical System Compatibility\u003c\/li\u003e\n\u003cli\u003eLegacy Electrical Equipment Applications\u003c\/li\u003e\n\u003cli\u003eEstablished Equipment Layouts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e H363DX\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Safety Switch\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSub-Category:\u003c\/strong\u003e Safety Switch\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 100 Amps\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Poles:\u003c\/strong\u003e 3\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed Voltage:\u003c\/strong\u003e 600V*\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 25.25 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 11.4 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 8.6 inches\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 25.25\"H × 11.4\"W × 8.6\"D\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor the H363DX Safety Switch, the available product information does not identify the enclosure material, internal component materials, UL listing details, CSA certification, or NEMA enclosure classification. Verify these details through manufacturer documentation or equipment markings rather than assuming them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy Electrical Installations\u003c\/li\u003e\n\u003cli\u003eExisting Electrical Distribution Systems\u003c\/li\u003e\n\u003cli\u003eCommercial Building Maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial Electrical Installations\u003c\/li\u003e\n\u003cli\u003eSafety Switch Replacement Projects\u003c\/li\u003e\n\u003cli\u003eThree-Pole Disconnect Applications\u003c\/li\u003e\n\u003cli\u003e100-Amp Electrical Systems\u003c\/li\u003e\n\u003cli\u003eEstablished Equipment Layouts\u003c\/li\u003e\n\u003cli\u003eElectrical Equipment Maintenance\u003c\/li\u003e\n\u003cli\u003eForm, Fit, and Function Matching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eSquare D® is a registered trademark of Schneider Electric. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Schneider Electric or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"SQUARE D","offers":[{"title":"New","offer_id":50366819467563,"sku":"H363DX","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50366819500331,"sku":"H363DX [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/h363dx","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}