{"product_id":"gfep230","title":"GFEP230 - 30 Amp GFCI (30mA) Circuit Breaker","description":"\u003cp\u003e\u003cstrong\u003eGFEP230 - 30 Amp GFCI (30mA) Circuit Breaker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen you’re dealing with equipment that can’t afford unnecessary shutdowns, the GFEP230 2-pole 30A circuit breaker is a practical, no-nonsense solution. It’s built with 30mA ground fault protection, which means it’s focused on protecting your equipment—not tripping every time there’s a minor fluctuation. That’s exactly what you want in commercial or industrial setups where downtime quickly turns into lost money. This breaker is designed for 125\/240VAC systems and handles typical loads with ease thanks to its 30 amp rating. It also provides 10kA interrupting capacity, so when a real fault occurs, it responds as it should. The size is compact enough to work into most panels without a fight, which is always a plus whether you’re replacing an existing unit or building something new. At the end of the day, this is the kind of breaker you install and don’t have to think about again—which is exactly the point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30mA ground fault protection aimed at protecting equipment (not overly sensitive)\u003c\/li\u003e\n\u003cli\u003eHelps avoid nuisance tripping in demanding environments\u003c\/li\u003e\n\u003cli\u003e2-pole design for standard 125\/240VAC applications\u003c\/li\u003e\n\u003cli\u003e30 amp capacity for reliable everyday use\u003c\/li\u003e\n\u003cli\u003e10kA interrupting rating for handling fault conditions\u003c\/li\u003e\n\u003cli\u003eSpace-saving design that fits easily into most panels\u003c\/li\u003e\n\u003cli\u003eSolid, consistent performance where it counts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e GFEP230\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 2\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 30A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 125\/240VAC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity:\u003c\/strong\u003e 10kA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Type:\u003c\/strong\u003e GFEP\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Fault Sensitivity:\u003c\/strong\u003e 30mA\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 3.19 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 2.0 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 2.5 in\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShip Weight:\u003c\/strong\u003e n\/a\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt to align with standard electrical safety expectations for ground fault equipment protection. Always check your local code requirements to ensure proper installation and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial panels and distribution systems\u003c\/li\u003e\n\u003cli\u003eHVAC units and refrigeration equipment\u003c\/li\u003e\n\u003cli\u003eMotor-driven machinery\u003c\/li\u003e\n\u003cli\u003eFacility lighting circuits\u003c\/li\u003e\n\u003cli\u003eAny setup where equipment protection matters more than ultra-sensitive trip levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"EATON","offers":[{"title":"New In Box","offer_id":51697266884907,"sku":"GFEP230","price":298.57,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/gfep230","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}