{"product_id":"frs-r-110","title":"FRS-R-110 - 110Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eFRS-R-110 - 110Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen your motor control centre or industrial panel demands dependable protection, the FRS‑R‑110 delivers performance you can trust. This 110 A fuse from the Eaton Bussmann Fusetron Class RK5 range is a dual‑element, time‑delay, current‑limiting design that helps equipment and systems keep running smoothly. With ratings of 600 V AC and 300 V DC, plus a high interrupting capacity, this fuse is well-suited for challenging commercial or industrial circuits. The intentional time delay at 500% of rated current means you can size closer to full‑load current and avoid nuisance trips caused by motor inrush or transformer energization. Whether you're working on a motor starter, control centre, or power distribution panel, the FRS‑R‑110 brings dependable circuit protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual‑element, time‑delay construction:\u003c\/strong\u003e Means the fuse tolerates short bursts of inrush current (such as motor starts) without tripping, so your system stays operational under transient loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent‑limiting behaviour:\u003c\/strong\u003e Helps reduce the energy let‑through in fault conditions, so downstream components see less stress and damage is minimized.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage ratings:\u003c\/strong\u003e Rated for both 600 V AC and 300 V DC service, with an interrupting capacity of 200 kA at 600 V AC and 20 kA at 300 V DC, this fuse is fit for heavy duty industrial duties.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon‑indicating, blade‑end × blade‑end termination:\u003c\/strong\u003e Simplifies installation in compatible fuse holders, maintaining a compact footprint in starter panels and fusible disconnects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass RK5 design:\u003c\/strong\u003e Means you can frequently use smaller components (switchgear, panels, starters) thanks to the time‑delay and current‑limiting features, reducing overall system cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 110 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 V AC \/ 300 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating:\u003c\/strong\u003e 200 kA at 600 V AC; 20 kA at 300 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e Minimum 10 seconds at 500% of rated current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Class:\u003c\/strong\u003e RK5.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Type:\u003c\/strong\u003e Blade end × blade end.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Length ~9.63 inches; Diameter ~1.61 inches.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 1.05 lbs (typical).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Compliance:\u003c\/strong\u003e Complies with UL 248‑12 for Class RK5 fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Certification:\u003c\/strong\u003e Certified to CSA C22.2 No. 248.12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marked:\u003c\/strong\u003e Meeting applicable European conformity requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe FRS‑R‑110 is ideal for industrial and commercial environments where motors, transformers, or other inductive loads cause temporary inrush current. Use it in combination starters, motor control centres, machinery disconnects, and power panelboards where you need both short‑circuit protection and selectivity for transient conditions. Because its time‑delay characteristic allows you to size closer to actual full‑load current, you’ll likely reduce nuisance trips and can opt for smaller starters, panels, and fuse blocks—saving space and lowering cost.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"New In Box","offer_id":50459192787243,"sku":"FRS-R-110","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459192820011,"sku":"FRS-R-110  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/0758\/1995\/files\/FRSR125_02copy_1.png?v=1745356965","url":"https:\/\/store.circuitbreakersuperstore.com\/products\/frs-r-110","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}