{"product_id":"ecsr110","title":"ECSR110 - 110Amp Fuse","description":"\u003cp\u003e\u003cstrong\u003eECSR110 - 110Amp Fuse\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf you’ve worked around electrical systems for any length of time, you know that power demand isn’t always smooth or predictable. Motors kick on, compressors surge, and HVAC systems cycle throughout the day—all creating brief spikes in current that are completely normal. The challenge is finding protection that understands the difference between a harmless surge and a real problem. That’s where the Eaton Edison ECSR100 Fuse comes in.\u003c\/p\u003e\n\u003cp\u003eThis 100 Amp Class RK5 dual-element time-delay fuse is built to handle those everyday conditions without overreacting. Instead of opening the circuit during routine startup surges, it allows equipment to get up and running without interruption. But when a true overload or fault occurs, it steps in quickly to help protect your wiring, equipment, and overall system.\u003c\/p\u003e\n\u003cp\u003eThe dual-element design is what makes it all work. It allows the fuse to distinguish between temporary inrush currents and actual fault conditions, so your system stays online when it should—and shuts down only when it needs to.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 Amp Class RK5 time-delay fuse for commercial and industrial applications\u003c\/li\u003e\n\u003cli\u003eSuper lag design helps handle short bursts of inrush current during startup\u003c\/li\u003e\n\u003cli\u003eReduces nuisance fuse openings caused by normal equipment operation\u003c\/li\u003e\n\u003cli\u003e600V rating suitable for a wide range of electrical systems\u003c\/li\u003e\n\u003cli\u003e200 kAIC interrupt rating for dependable fault protection\u003c\/li\u003e\n\u003cli\u003eDual-element construction supports controlled time-delay performance\u003c\/li\u003e\n\u003cli\u003eIdeal for HVAC systems, motor control centers, and OEM machinery\u003c\/li\u003e\n\u003cli\u003eHelps improve system uptime and reduce maintenance interruptions\u003c\/li\u003e\n\u003cli\u003eNon-indicating design for simple, straightforward replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Eaton\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Edison ECSR\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e ECSR100\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Fuse\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Class:\u003c\/strong\u003e RK5\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage Rating:\u003c\/strong\u003e 100 A\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600 V\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Rating:\u003c\/strong\u003e 200 kAIC\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 10 seconds at 500% overload\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial Features:\u003c\/strong\u003e Super lag, time lag, non-current limiting\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Elements:\u003c\/strong\u003e Dual-element\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-indicating\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Type:\u003c\/strong\u003e Standard\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.63 in L × 1.61 in W × 1.61 in H\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 lb\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e CE Marked\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis fuse is CE Marked and manufactured with attention to Eaton’s quality standards. It’s intended for use in properly rated electrical systems and should always be installed in accordance with applicable electrical codes and best practices. When installed according to electrical codes, you can have confidence that this unit adheres to expected construction and compliance benchmarks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere It Works Best\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe ECSR100 is a strong fit for systems where electrical loads change throughout normal operation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotor control centers (MCCs)\u003c\/li\u003e\n\u003cli\u003eHVAC and refrigeration systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation equipment\u003c\/li\u003e\n\u003cli\u003eOEM machinery and production lines\u003c\/li\u003e\n\u003cli\u003eElectrical distribution panels\u003c\/li\u003e\n\u003cli\u003ePump and compressor systems\u003c\/li\u003e\n\u003cli\u003eCommercial and light industrial circuits\u003c\/li\u003e\n\u003cli\u003eFacility-wide power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\n\u003cdiv\u003e\n\u003cblockquote\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eUse of Original Equipment Manufacturer (OEM) trademarks, names, and logos is for informational and identification purposes only. This does not imply any affiliation, sponsorship, endorsement, or approval by the original equipment manufacturer.\u003cstrong\u003e CIRCUIT BREAKER SUPERSTORE®\u003c\/strong\u003e is an independent reseller and is \u003cstrong\u003enot \u003c\/strong\u003ean authorized distributor, affiliate, or representative of any manufacturer. Manufacturer warranties do \u003cstrong\u003enot\u003c\/strong\u003e apply unless expressly stated. All trademarks and registered trademarks are the property of their respective owners.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cem\u003eEaton®, Cutler-Hammer®, Westinghouse®, Challenger®, Bussmann®, Crouse-Hinds®, and Cooper® are registered trademarks of Eaton Corporation plc. Products sold are surplus, used, or refurbished and are \u003cstrong\u003eNOT \u003c\/strong\u003esupplied by Eaton Corporation plc or its affiliates.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"New In Box","offer_id":50459170963755,"sku":"ECSR110","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished","offer_id":50459170996523,"sku":"ECSR110  [R]","price":0.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/store.circuitbreakersuperstore.com\/products\/ecsr110","provider":"CIRCUIT BREAKER SUPERSTORE®","version":"1.0","type":"link"}